首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Measurements of the linewidth of a continuous-wave distributed feedback quantum cascade laser
Authors:Vasili L Kasyutich  Philip A Martin
Institution:
  • a School of Chemical Engineering and Analytical Science, University of Manchester, Oxford Road, M13 9PL, UK
  • b Institute of Quantum Electronics, HPF F16, ETHZ, Schafmattstrasse 16, 8093, Zurich, Switzerland
  • Abstract:Two-sample (Allan) variance with a modified algorithm was applied to the determination of the experimental linewidth of a thermoelectrically-cooled continuous-wave distributed feedback quantum cascade laser at a wavelength of 4.333 μm. From successive laser transmittance scans over the CO2 ν3, (0111 − 0110) P(33) absorption line at 2307.653 cm− 1, two-sample variances were calculated for the laser frequency difference between different points on the sides of the absorption peak. From the minimum two-sample variance of the laser frequency difference between two adjacent points (5 μs between the points) on the same side of the absorption line the experimental laser linewidth was estimated to be less than 36(7) kHz at a laser power of ~ 25 mW, a laser current of 976 mA and a laser temperature of + 19.5 °C.
    Keywords:Quantum cascade laser  Laser linewidth  Two-sample variance
    本文献已被 ScienceDirect 等数据库收录!
    设为首页 | 免责声明 | 关于勤云 | 加入收藏