首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Experimental analysis of the electrode products emitted byhigh-current vacuum arcs
Authors:Kutzner  J Batura  R Stachowiak  Z
Institution:Inst. of Electr. Power Eng., Poznan Tech. Univ. ;
Abstract:The mass distribution of particles produced in the high-current vacuum arc was investigated. The experiments were concentrated on evaluating the spatial mass distribution emitted in the radial as well as in the azimuthal directions calculated from the mass deposition profile on collectors surrounding the arc discharge. The experiments were carried out in a vacuum chamber evacuated to an ambient pressure <10-4 Pa. High-current arcs in the range from 2-7.5 kA were drawn between butt contacts of 31 and 55 mm in diameter (anode and cathode, respectively) both of a copper-chromium alloy (CuCr25). The surface mass deposited along multi-segment collectors was measured by a micro densitometer, and an inductively coupled plasma (ICP) spectrometer. Two angular mass deposit distributions were determined: the azimuthal distribution on the plane parallel to the cathode surface, and the radial distribution as a function of the angle with respect to the cathode plane. Both distributions were anisotropic and the structure of the deposition layer depended on the angle of incidence of the particles onto the substrate, the density of the particle flux and other factors. The mass deposited on the collectors consisted mostly of chromium molecules (approx. 80% of Cr and 20% Cu) for CuCr25 or CuCr40 electrodes
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号