Study of a circuit-breaker arc with self-generated flow. III. Thepost-arc phase
Abstract:For pt.II see ibid., vol.16, p.615-22, 1988. The third part of this study of a circuit-breaker arc with self-generated flow concerns the model of the post-arc phase. The greater interruption capability of SF6 compared to N2, already suggested in pt.II, is confirmed by the following results: amplitude and duration of the postarc current are much lower in SF6 and the maximum value of the rate of rise of recovery voltage is about three times higher in SF6 than in N2. The model also predicts the existence of a plateau in post-arc current variation and the original behavior of this type of circuit-breaker: interrupting efficiency increases with the current peak in the initial phase