首页 | 本学科首页   官方微博 | 高级检索  
     检索      

锂玻璃探测器中子探测效率的刻度
引用本文:张奇玮,贺国珠,阮锡超,李霞,任杰,周祖英.锂玻璃探测器中子探测效率的刻度[J].原子核物理评论,2013,30(2):156-160.
作者姓名:张奇玮  贺国珠  阮锡超  李霞  任杰  周祖英
作者单位:中国原子能科学研究院,北京 102413
基金项目:中国核工业集团公司预先研究基金(61601090405)@@@@Foundation item:Advance Research Fund of China National Nuclear Corporation
摘    要:为了精确测量keV能区的中子俘获截面,中国原子能科学研究院正在建造一台4π 全吸收型γ 探测装置---GTAF,锂玻璃探测器将会作为中子束流监视器测量中子能谱。利用5SDH-2 加速器刻度了锂玻璃探测器在两个入射中子单能点(250 和565 keV) 的探测效率,并使用EANT4 和MCNP 程序模拟计算了锂玻璃探测器的相对探测效率。通过归一化实验数据和模拟结果,得到了锂玻璃探测器在10keV~1 MeV 能区的中子探测效率曲线。对于把锂玻璃探测器测量得到的飞行时间谱转化为中子束流能谱,是一项非常重要的工作,同时为探测器效率刻度提供了新方法。In order to accurately measure the neutron capture cross section in the energy range of keVMeV, 4 πgamma-ray total absorption facility (GTAF) is being constructed at China Institute of Atomic Energy (CIAE). The lithium glass detector will be used as a neutron beam monitor for GTAF. The detection efficiency of the lithium glass detector at two incident neutron energy points (250, 565 keV) was calibrated in 5SDH-2 accelerator, and the relative detection efficiency was simulated by GEANT4 and MCNP code. By the normalization of the experimental data and simulation result, the neutron detection efficiency curve of the lithium glass detector between 10 keV and 1 MeV was obtained. This work will be important to convert the Time-of-flight spectrum that be measured by Li-glass detector to the energy spectrum of neutron beam, and provide the new method for calibration of detection efficiency.

关 键 词:γ-全吸收型探测装置    锂玻璃探测器    探测效率    GEANT4    MCNP
收稿时间:1900-01-01

Calibration of Neutron Detection Efficiency of Li-glass Detector
ZHANG Qiwei , HE Guozhu , RUAN Xichao , LI Xia , REN Jie , ZHOU Zuying.Calibration of Neutron Detection Efficiency of Li-glass Detector[J].Nuclear Physics Review,2013,30(2):156-160.
Authors:ZHANG Qiwei  HE Guozhu  RUAN Xichao  LI Xia  REN Jie  ZHOU Zuying
Institution:China Institute of Atomic Energy, Beijing 102413, China
Abstract:In order to accurately measure the neutron capture cross section in the energy range of keVMeV, 4 πgamma-ray total absorption facility (GTAF) is being constructed at China Institute of Atomic Energy (CIAE). The lithium glass detector will be used as a neutron beam monitor for GTAF. The detection efficiency of the lithium glass detector at two incident neutron energy points (250, 565 keV) was calibrated in 5SDH-2 accelerator, and the relative detectionefficiency was simulated by GEANT4 and MCNP code. By the normalization of the experimental data and simulation result, the neutron detection efficiency curve of the lithium glass detector between 10 keV and 1 MeV was obtained. This work will be important to convert the Time-of-flight spectrum that be measured by Li-glass detector to the energy spectrum of neutron beam, and provide the new method for calibration of detection efficiency.
Keywords:gamma-ray total absorption facility  Li-glass detector  detection efficiency  GEANT4  MCNP
本文献已被 万方数据 等数据库收录!
点击此处可从《原子核物理评论》浏览原始摘要信息
点击此处可从《原子核物理评论》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏