摘    要:介绍了重离子治癌装置的最新发展状况 ,比较了两类典型的旋转机架的结构及光学特性 ,给出了离子光学的限制条件 .设计了一台桶形机架 ,为兰州重离子冷却储存环应用于医学治疗进行了预研. A simple plane rotating gantry is proposed at the Heavy Ion Research Facility in Lanzhou (HIRFL), where a new project named Cooling Storage Ring is under construction. The gantry is 18 metre long, 5 metre high from upper beam axes to rotation axes. It consists of eight quadruples, two 45° and one large aperture 90° dipole magnets. It is equipped with a two direction magnetic raster scanning system. A beam spot of radii between 2 to 5 mm can be achieved at∶...

关 键 词:重离子治癌    旋转机架    离子光学
文章编号:1007-4627(2001)02-0116-04
收稿时间:1900-01-01
修稿时间:2001年2月20日

Rotating Gantry Studies for Heavy Ion Tumor Therapy in Lanzhou
SONG Ming-Tao,ZHAN Wen-long,WEI Bao-wen,YANG Xiao-dong,XIA Jia-wen,ZHANG Wen-zhi,YUAN You-jin.Rotating Gantry Studies for Heavy Ion Tumor Therapy in Lanzhou[J].Nuclear Physics Review,2001,18(2):116-119.
Authors:SONG Ming-Tao  ZHAN Wen-long  WEI Bao-wen  YANG Xiao-dong  XIA Jia-wen  ZHANG Wen-zhi  YUAN You-jin
Institution:Institute of Modern Physics; the Chinese Academy of Sciences; Lanzhou 730000; China
Abstract:A simple plane rotating-gantry is proposed at the Heavy Ion Research Facility in Lanzhou (HIRFL), where a new project named Cooling Storage Ring is under construction. The gantry is 18-metre-long, 5-metre-high from upper beam axes to rotation axes. It consists of eight quadruples, two 45° and one large aperture 90° dipole magnets. It is equipped with a two-direction magnetic raster scanning system. A beam spot of radii between 2 to 5 mm can be achieved at expected transverse emittance ratios up to 1∶ 5(5∶ 1) at any rotation angle within momentum spread 0.2%. The beam size control and achromaticity at the gantry isocenter are realized by gantry optics with little help from upstream transfer line. The constraints on ion-optics and coming beam parameters for a rotation-independent beam spot are derived analytically.
Keywords:heavy ion tumor therapy  rotating gantry  ion optics