光纤微机电系统法布里-珀罗压力传感器的波分复用
引用本文:倪小琦,王鸣,陈绪兴,戴霞娟.光纤微机电系统法布里-珀罗压力传感器的波分复用[J].光学学报,2007,27(5):76-780.
作者姓名:倪小琦  王鸣  陈绪兴  戴霞娟
作者单位:南京师范大学物理科学与技术学院光电技术省重点实验室,南京,210097
基金项目:国家自然科学基金(50375074),江苏省高技术研究计划(BG2003024)资助课题
摘    要:提出了一种用阵列波导光栅复用光纤微机电系统法布里-珀罗压力传感器的方法,实现了法布里-珀罗压力传感器的准分布式测量。传感器基于法布里-珀罗腔干涉的原理,采用微机电系统技术加工制作,用双波长方法解调干涉信号,利用传感器对两个不同波长光的反射率的比值与压力的单值关系确定所施加压力的大小,用阵列波导光栅实现传感器复用。理论分析与实验验证了传感器解调和复用的基本原理。实验结果表明:在压力的线性测量范围(0~1.5 MPa)内,系统的灵敏度(相对反射率比值/压力)可达到0.02026 MPa-1,测量结果具有较好的线形性,相对反射率比值的标准偏差小于3×10-4。该系统可以补偿传感器光网中和波长无关的变动引起的误差,具有好的线性、灵敏度和精度,复用能力强且复用传感器间无串扰。

关 键 词:导波与光纤光学  法布里-珀罗传感器的复用  双波长解调  微机电系统  阵列波导光栅
文章编号:0253-2239(2006)05-0776-05
收稿时间:2006/5/9
修稿时间:2006-05-09

Wavelength Multiplexing of Optical Fiber Microelectromechanical System Fabry-Pérot Pressure Sensors
Ni Xiaoqi,Wang Ming,Chen Xuxing,Dai Xiajuan.Wavelength Multiplexing of Optical Fiber Microelectromechanical System Fabry-Pérot Pressure Sensors[J].Acta Optica Sinica,2007,27(5):76-780.
Authors:Ni Xiaoqi  Wang Ming  Chen Xuxing  Dai Xiajuan
Institution:Jiangsu Provincial Key Laboratory of Optoelectronic Technology, School of Physical Science and Technology, Nanjing Normal University, Nanjing 210097
Abstract:In order to realize the quasi-distributed measurement for Fabry-Pérot (F-P) sensors, a multiplexing scheme of optical fiber microelectromechanical system (MEMS) Fabry-Pérot pressure sensors with arrayed waveguide grating is presented. Based on Fabry-Pérot interferometry, the sensors are fabricated with microelectromechanical system techniques and interrogated with the dual-wavelength method. In this method, the single-valued relation between ratio of sensor reflectance at two different wavelengths and the calibrated pressure are used to determine the pressure. The arrayed waveguide grating (AWG) is used to multiplex the sensors. The demodulation and multiplexing principles are theoretically analyzed and experimentally verified. The experimental results demonstrate that in the linear measurement range of pressure (0~1.5 MPa), the sensitivity (ratio of sensor reflectivity/pressure) of the system achieves 0.02026 MPa-1, the measured ratio has a good linearity with the pressure, and the standard deviation of the reflectance ratio is less than 3×10-4. The system can eliminate errors resulted from wavelength-independent variations in the fiber interconnection to the sensor,and has reasonable linearity, sensitivity and precision. Many sensors can be multiplexed in this system and there is no observable crosstalk among them.
Keywords:guided wave and fiber optics  multiplexing of Fabry-Pé  rot pressure sensors  dual-wavelength demodulation  microelectromechanical system  arrayed waveguide grating