首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基于上转换发光技术的生物传感器及其应用
引用本文:赵永凯,周蕾,黄惠杰,杨瑞馥,黄立华,任冰强,卢健,王向朝.基于上转换发光技术的生物传感器及其应用[J].光学学报,2005,25(6):41-847.
作者姓名:赵永凯  周蕾  黄惠杰  杨瑞馥  黄立华  任冰强  卢健  王向朝
作者单位:中国科学院上海光学精密机械研究所,上海,201800;中国科学院研究生院,北京,100049;军事医学科学院微生物流行病研究所,北京,100071;中国科学院上海光学精密机械研究所,上海,201800
基金项目:国家自然科学基金(60378024)资助课题。
摘    要:为实现对特定生物分子的高灵敏度快速检测与分析。采用上转换发光材料作为标记物,研制成功一台基于上转换发光技术的新型光学免疫生物传感器。该传感器利用上转换发光材料在红外光激发下发射可见磷光的特性,通过对免疫层析试纸条上经生物反应而结合上去的上转换发光材料颗粒的含量进行检测,计算出被测样品中特定生物分子的浓度。实验结果表明,该传感器具有较好的生物特异性,对兔抗鼠疫免疫球蛋白(IgG)标准样品的检测灵敏度达到ng/ml量级,并在200~6000ng/ml浓度范围内具有良好的线性响应特性,相关系数R^2≥0.95;对鼠疫耶尔森氏菌抗体的敏感性明显高于间接血凝实验,且与免疫印迹检测实验结果具有较好的一致性。该传感器具有稳定、可靠、灵敏的工作性能,符合实际检测与分析的要求。

关 键 词:光学计量  传感器技术  生物传感器  上转换发光技术  上转换发光材料
收稿时间:2004/9/13

Up-Converting Phosphor Technology-Based Biosensor and Its Application
Zhao Yongkai,Zhou Lei,Huang Huijie,YANG Ruifu,HUANG Lihua,Ren Bingqiang,Lu Jian,Wang Xiangzhao.Up-Converting Phosphor Technology-Based Biosensor and Its Application[J].Acta Optica Sinica,2005,25(6):41-847.
Authors:Zhao Yongkai  Zhou Lei  Huang Huijie  YANG Ruifu  HUANG Lihua  Ren Bingqiang  Lu Jian  Wang Xiangzhao
Institution:Zhao Yongkai~1,3 Zhou Lei2 Huang Huijie1 Yang Ruifu2 Huang Lihua1Ren Bingqiang1 Lu Jian~1,3 Wang Xiangzhao11 Shanghai Institute of Optics and Fine Mechanics,The Chinese Academy of Sciences,Shanghai 2018002 Institute of Microbiology and Epidemiology,Academy of Military Sciences,Beijing 1000713 Graduate School,The Chinese Academy of Sciences,Beijing 100049
Abstract:An up-converting phosphor technology-based biosensor (UPT-based biosensor) was developed for immunoassay and fast detecting using up-converting phosphor (UCP) as the biological marker. UCP can emit visible light when excited by infrared light. Through detecting and analyzing the content of UCP particle on the test strip after immunoreaction, the UPT-based biosensor can obtain the concentration information of target analyte in the sample. The UPT system realized the quantitative detection and had good ability to meet the need of some emergencies. High sensitivity (nanogram/ml), good linear relationship in the concentration range of 200~6000 ng/ml and an excellent correlation (R2≥0.95) were verified by quantitative detection results. The sensitivity of the UPT-based biosensor was better than that of the indirect hemagglutination test in the practical application. All the results were comparable with that obtained by Western Blot detection. The UPT-based biosensor had stable, reliable and sensitive working performances, and it can meet the need of some various applications such as rapid immunoassay, chemical and biological detection and so on.
Keywords:optical metrology  sensor technology  biosensor  up-converting phosphor technology  up-converting phosphor material
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号