首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Non-rigid landmark-based large-scale image registration in 3-D reconstruction of mouse and rat kidney nephrons
Institution:2. Department of Biomedical Engineering, China Medical University, Shenyang, China;3. China Medical University, Department of Histology and Embryology, China Medical University, Shenyang, China;4. Department of Biomedicine – Anatomy, Aarhus University, Aarhus, Denmark
Abstract:BackgroundSerial histological sections are suffering from mechanical distortions that disturb the reconstruction of 3-D objects. We have corrected such artifacts with a non-rigid landmark-based method that respects the original geometry in the tissue block. The method is exemplified on a large scale in the registration of semi-thin serial sections of the mouse and rat kidneys, and has been tested on FFPE-sections.AimIn this study of mouse and rat kidneys, we have measured and characterized the deformations introduced in the preparation of 2.5-μm-thick Epon sections and then eliminated them by a landmark-based non-rigid transformation (NRT).MethodsWe obtained 2.5-μm-thick serial Epon sections from three mouse kidneys and three rat kidneys for 3-D reconstruction of the nephron tubules. First, the images from 3000 serial mouse and 13,000 serial rat sections underwent a classic rigid registration (CRR), and the distortions were measured and indexed. The section images underwent a further NRT in order to compensate for the deformations. The NRT used is a classic interactive landmark-based approach. The quality of the NRT was verified by comparing the geometry of the transformed images with corresponding block images.ResultsAfter CRR, the 2.5-μm-thick sections had a linear deformation of up to 2%, the tubular lengths were overestimated with up to 1.5×, and it was most difficult to trace the tubules from section to section. After the additional NRT, the geometry of the images reflected the original geometry in the block, the tubular lengths were no longer overestimated, and the NRT highly facilitated the tracing of the tubular system.ConclusionsNRT has facilitated the tracing of the tubular system in kidneys, a tracing, which would otherwise have been most difficult to perform. NRT has yielded substantial new knowledge to segmental and spatial nephron organization in the mouse and rat kidneys.
Keywords:Alignment  Histological  Semi-thin  Epon  Serial sections
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号