首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基于激光诱导水拉曼抑制法的油膜厚度测量方法研究
引用本文:陈宇男,杨瑞芳,赵南京,祝 玮,陈晓伟,张瑞琦.基于激光诱导水拉曼抑制法的油膜厚度测量方法研究[J].光谱学与光谱分析,2022,42(12):3954-3962.
作者姓名:陈宇男  杨瑞芳  赵南京  祝 玮  陈晓伟  张瑞琦
作者单位:1. 环境光学与技术重点实验室,中国科学院安徽光学精密机械研究所,安徽 合肥 230031
2. 中国科学技术大学,安徽 合肥 230026
3. 安徽省环境光学监测技术重点实验室,安徽 合肥 230031
基金项目:supported by National Natural Science Foundation (61805255, 61378041), National Key R&D Program of China (2017YFF0108402, 2016YFC1400602), Anhui Natural Science Foundation (1808085MF208), Anhui Key Research and Development Plan Project(1804a0802192), Anhui Province Science and Technology Major Project (17030801033)
摘    要:为了实现水体表面油膜厚度的快速测量分析,以266 nm的激光作为探测系统的激发光源,基于激光诱导水拉曼散射光谱检测技术,通过获取不同种类不同厚度油膜存在下水拉曼光谱信息,建立油膜厚度反演模型。采用高斯函数拟合法校正了荧光光谱对拉曼光谱的干扰。然后根据水拉曼抑制法结合非线性最小二乘优化算法,建立油膜厚度反演模型。结果表明:对92#汽油、0#柴油、美孚机油20w-40、壳牌润滑油10w-40、采埃孚变速箱油AG6和原油油膜能探测到的油膜厚度范围为0.19~379.22 μm。采用水拉曼光谱-油膜厚度反演模型预测油膜厚度的平均相对误差在8.14%~15.81%之间。该方法能实现实验室条件下对微米级油膜的测量。

关 键 词:油膜厚度  拉曼光谱  快速检测  
收稿时间:2021-01-26

Research on Measuring Oil Film Thickness Based on Laser-Induced Water Raman Suppression Method
CHEN Yu-nan,YANG Rui-fang,ZHAO Nan-jing,ZHU Wei,CHEN Xiao-wei,ZHANG Rui-qi.Research on Measuring Oil Film Thickness Based on Laser-Induced Water Raman Suppression Method[J].Spectroscopy and Spectral Analysis,2022,42(12):3954-3962.
Authors:CHEN Yu-nan  YANG Rui-fang  ZHAO Nan-jing  ZHU Wei  CHEN Xiao-wei  ZHANG Rui-qi
Institution:1. Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine MechanicsChinese Academy of Sciences, Hefei 230031, China 2. University of Science and Technology of China, Hefei 230026, China 3. Key Laboratory of Optical Monitoring Technology for Environment, Hefei 230031, China
Abstract:In this work, using a 266 nm laser as the excitation light source of the detection system, the water Raman spectra under the oil film of different thicknesses were obtained based on the laser-induced water Raman spectroscopy technology. The Gaussian function fitting method was used to correct the interference of the fluorescence spectrum on the Raman spectrum. And then, the oil film thickness inversion model could be established according to the water Raman suppression method combined with the nonlinear least square optimization algorithm. The results show that the six oils’ detectable oil film thickness range (92# gasoline, 0# diesel, Mobil oil 20w-40, Shell Helix10w-40, Lifeguard Fluid AG6 and crude oil) is from 0.19 to 379.22 μm. The average relative error of oil film thickness prediction ranges from 8.14% to 15.81% according to the water Raman spectrum-oil film thickness inversion model. This method can realize the measurement of micron-level oil film under laboratory conditions.
Keywords:Oil film thickness  Raman spectroscopy  Rapid detection  
点击此处可从《光谱学与光谱分析》浏览原始摘要信息
点击此处可从《光谱学与光谱分析》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号