时间分辨激光荧光光谱技术在免疫分析中的应用
引用本文:潘利华,杜继贤,谢文兵,杜庆洋,恽勤.时间分辨激光荧光光谱技术在免疫分析中的应用[J].光谱学与光谱分析,2000,20(3):277-279.
作者姓名:潘利华  杜继贤  谢文兵  杜庆洋  恽勤
作者单位:中国科学院长春应用化学研究所,国家电化学和光谱研究分析中心,130022,长春
摘    要:本研究以时间分辨激发荧光光谱分析技术为基础 ,进行稀土离子标记的激光激发的时间分辨荧光免疫分析 (TRFIA)研究。实验以自行合成的二乙三胺五醋酸酐 (DTPAA)为双功能螯合剂。用 Eu3+标记兔抗人 (RAH) Ig G抗体 ,依据解离增强原理 (DEL FIA) ,研究了 Eu3+ -β萘甲酰三氟丙酮 (β- NTA)的荧光分辨体系 ,测定了荧光光谱和荧光寿命 ,建立了铕离子分析检出方法 ,其工作曲线范围为 1× 10 - 7~ 1× 10 - 1 1g· m L- 1 ,检测限为 1× 10 - 1 3g· m L- 1 ,相对标准偏差为 6 .4%。结合 TRFIA方法学研究 ,进行了人血清丙型肝炎病毒抗体 (Anti- HCV)检测。并同酶联免疫法 (EL ISA)对比。取得 TRFIA法阳性检测率明显高于EL ISA法的结果。

关 键 词:稀土标记  荧光免疫分析  时间分辨荧光光谱

Laser-Time-Resolved Fluorescence Spectroscopy in Immunoassays
Lihua PAN,Jixian DU,Wenbing XIE,Qingyang DU,Qin YUN.Laser-Time-Resolved Fluorescence Spectroscopy in Immunoassays[J].Spectroscopy and Spectral Analysis,2000,20(3):277-279.
Authors:Lihua PAN  Jixian DU  Wenbing XIE  Qingyang DU  Qin YUN
Institution:National Analytical Research Center of Eletrochemistry and Spectroscopy, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 130022 Changchun.
Abstract:This paper described a laser-excited time-resolved fluoroimmunoassay set. It made lanthanide ion to couple the anhydrde of diethylenetriaminepentaacetic acid (DTPAA) for labeling antibodies. The experiment used polystyrene tap coated with HCV antigen as the solid phase and a chelate of the rare earth metal europium as fluorescent label. A nitrogen laser beam was used to excite the Eu3- chelates and after 60 microseconds delay time, the emission fluorescence was measured. Background fluorescence of short lifetimes caused by serum components and Raman scattering can be eliminated by set the delay time. In the system condition, fluorescent spectra and fluorescent lifetimes of Eu3+ beta-naphthoyltrifluroacetone (NTA) chelates were measured. The fluorescent lifetime value is 650 microseconds. The maximum emission wavelength is 613 nm. The linear range of europium ion concentration is 1 x 10(-7)-1 x 10(-11) g.mL-1 and the detection limit is 1 x 10(-13) g.mL-1. The relative standard deviation of determination (n = 12) for samples at 0.01 ng.mL-1 magnitude is 6.4%. Laser-TRFIA was also found to be suitable for diagnosis of HCV. The sensitivity and specificity were comparable to enzyme immunoassay. The result was obtained with laser-TRFIA for 29 human correlated well with enzyme immunoassay.
Keywords:Time-resolved fluorescence    Laser    Immunoassa y    Europium labels  
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号