基金项目:国家(863计划)项目,中央高校基本科研业务项目
摘    要:利用可调谐激光二极管吸收光谱技术进行气体检测时,波长调制伴随的光强幅度调制,会使解调出的谐波谱线发生畸变.在傅里叶分析的基础上对可调谐激光二极管吸收光谱任意调制幅度的波长调制光谱信号进行了分析,给出了光强幅度调制引起吸收谱线畸变的理论解释.提出了在波长调制过程中进行旧步平抑幅度调制的方法来消除谱线畸变,设计了实验方案并...

关 键 词:可凋谐激光二极管吸收光谱  波长调制  信号分析  谐波  谱线畸变校正

Signal analysis and spectrum distortion correction for tunable diode laser absorption spectroscopy system
Bao WY,Zhu Y,Chen J,Chen JQ,Liang B.Signal analysis and spectrum distortion correction for tunable diode laser absorption spectroscopy system[J].Spectroscopy and Spectral Analysis,2011,31(4):1015-1019.
Authors:Bao Wei-Yi  Zhu Yong  Chen Jun  Chen Jun-Qing  Liang Bo
Institution:The Key Laboratory for Optoelectronic Technology & System, Ministry of Education, Opto-Electronic Engineering College of Chongqing University, Chongqing 400044, China. osijr0572cn@yahoo.com.cn
Abstract:In the present paper, the signal of a tunable diode laser absorption spectroscopy (TDLAS) trace gas sensing system, which has a wavelength modulation with a wide range of modulation amplitudes, is studied based on Fourier analysis method. Theory explanation of spectrum distortion induced by laser intensity amplitude modulation is given. In order to rectify the spectrum distortion, a method of synchronous amplitude modulation suppression by a variable optical attenuator is proposed. To validate the method, an experimental setup is designed. Absorption spectrum measurement experiments on CO2 gas were carried out. The results show that the residual laser intensity modulation amplitude of the experimental system is reduced to -0.1% of its original value and the spectrum distortion improvement is 92% with the synchronous amplitude modulation suppression. The modulation amplitude of laser intensity can be effectively reduced and the spectrum distortion can be well corrected by using the given correction method and system. By using a variable optical attenuator in the TDLAS (tunable diode laser absorption spectroscopy) system, the dynamic range requirements of photoelectric detector, digital to analog converter, filters and other aspects of the TDLAS system are reduced. This spectrum distortion correction method can be used for online trace gas analyzing in process industry.