首页 | 本学科首页   官方微博 | 高级检索  
     检索      

二极管阵列检测-流动注射分光光度法同时测定食品中铁铜钴
引用本文:米建萍,黎源倩,邹晓莉,郑波,杨经国.二极管阵列检测-流动注射分光光度法同时测定食品中铁铜钴[J].光谱学与光谱分析,2007,27(6):1188-1191.
作者姓名:米建萍  黎源倩  邹晓莉  郑波  杨经国
作者单位:1. 四川大学华西公共卫生学院卫生检测教研室,四川 成都 610041
2. 四川大学物理科学与技术学院,四川 成都 610064
摘    要:目的在于建立同时测定食品中铁、铜、钴三种微量元素的新方法。以2-(5-溴-2-吡啶偶氮)-5-二乙氨基酚(5-Br-PADAP)为显色剂,Triton X-100为增敏剂,采用流动注射-CCD二极管阵列检测-分光光度分析法同时对其进行测定。优化了实验参数,并用偏最小二乘法计算程序解析重叠光谱。结果显示,铁、铜和钴的线性范围分别为0.2~10 μg·mL-1,0.1~5.0 μg·mL-1,0.01~1.0 μg·mL-1,检出限分别为:0.2,0.1,0.01 μg·mL-1,进样频率为45样·h-1。所建方法用于茶叶、芝麻、小米等食品测定时,样品加标回收率分别为铁89.4%~102.3%、铜92.2%~108.0%、钴93.2%~110.8%,相对标准偏差为1.1%~12.1%。对国家一级标准参考物质茶叶和桃叶进行测定(=8),结果在其给出的保证值范围之内。

关 键 词:流动注射分析  二极管阵列检测  偏最小二乘法  食品分析        
文章编号:1000-0593(2007)06-1188-04
收稿时间:2006-05-28
修稿时间:2006-05-282006-09-02

Simultaneous Determination of Iron,Copper and Cobalt in Food Samples by Diode Array Detection-Flow Injection Analysis Using Partial Least Squares Calibration Model
MI Jian-ping,LI Yuan-qian,ZOU Xiao-li,ZHENG Bo,YANG Jing-guo.Simultaneous Determination of Iron,Copper and Cobalt in Food Samples by Diode Array Detection-Flow Injection Analysis Using Partial Least Squares Calibration Model[J].Spectroscopy and Spectral Analysis,2007,27(6):1188-1191.
Authors:MI Jian-ping  LI Yuan-qian  ZOU Xiao-li  ZHENG Bo  YANG Jing-guo
Institution:MI Jian-ping,LI Yuan-qian,ZOU Xiao-li,ZHENG Bo,YANG Jing-guo
Abstract:A flow injection-CCD-diode array detection spectrophotometric method using partial least squares (PLS) algorithm for the simultaneous determination of iron, copper and cobalt in food samples has been established. The method was based on the chromogenic reaction between metallic ions and 5-Br-PADAP in the presence of acetic acid-acetic sodium buffer solution (pH 5) containing 30 g x L(-1) ascorbic acid and 2% (phi) Triton X-100. The overlapped spectra of these complexes were collected by CCD diode array detector and the multi-wavelength absorbance data were processed using partial least squares algorithm. The reaction conditions and analytical parameters of FIA were investigated. The food samples can be analyzed without any separation after digestion, and the sampling rate was 45 x h(-1). The linear ranges of Fe2+, Cu+ and Co2+ were 0.2-10.0 microg x mL(-1), 0.1-5.0 microg x mL(-1), and 0.01-1.0 microg x mL(-1) and the detection limits were 0.2, 0.1 and 0.01 microg x mL(-1), respectively. The average recoveries of spiked samples were 89.4%-110.8% for the three elements. The relative standard deviation (RSD) of samples was in the range of 1.1%-12.1%. Comparing the proposed method with ICP-AES, the relative error was below 12.1%. Above all, this method is simple, quick, sensitive, selective, and easy to be apply and generalize.
Keywords:Iron  Copper  Cobalt  FIA  CCD-diode array detection  PLS  Food analysis  5-Br-PADAP
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《光谱学与光谱分析》浏览原始摘要信息
点击此处可从《光谱学与光谱分析》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号