首页 | 本学科首页   官方微博 | 高级检索  
     检索      

大尺度区域水汽浓度激光检测方法的研究
引用本文:何莹,张玉钧,王立明,尤坤,周毅,孙晓敏,刘振民.大尺度区域水汽浓度激光检测方法的研究[J].光谱学与光谱分析,2013,33(3):608-612.
作者姓名:何莹  张玉钧  王立明  尤坤  周毅  孙晓敏  刘振民
作者单位:1. 中国科学院环境光学与技术重点实验室,中国科学院安徽光学精密机械研究所,安徽 合肥 230031
2. 中国科学院生态系统网络观测与模拟重点实验室,中国科学院地理科学与资源研究所,北京 100101
基金项目:中国科学院知识创新工程重要方向项目(KZCX2-YW-JS408);中国科学院重大科研装备研制项目(YZ200709);中国科学院合肥物质科学研究院青年人才基金项目(Y03RC21122)资助
摘    要:为了实现大尺度区域下大气中水汽浓度的高灵敏度、高精确性、快速响应检测,与遥感反演的数据进行校正,采用了TDLAS直接吸收技术结合开放式监测的方法。选择水汽分子在1.27 μm附近的单根吸收谱线为目标谱线,设计了大尺度区域水汽激光检测系统。结合多次反射池验证了系统性能,40 m光程下极限灵敏度为14.803 mmol·mol-1。利用本系统在中国科学院禹城综合试验站完成了1 420 m光程下的连续外场实验,系统工作稳定,并与同场地涡度相关观测系统中的气体分析仪LI-7500的测量数据进行了对比,数据一致性较好。为在复杂野外非均匀下垫面的水汽浓度变化的监测提供新方法。

关 键 词:激光吸收光谱  开放光路  水汽  大尺度区域    
收稿时间:2012-07-19

Study on Large-Scale Regional Laser Detection Methods for Water Vapor Concentration
HE Ying,ZHANG Yu-jun,WANG Li-ming,YOU Kun,ZHOU Yi,SUN Xiao-min,LIU Zhen-min.Study on Large-Scale Regional Laser Detection Methods for Water Vapor Concentration[J].Spectroscopy and Spectral Analysis,2013,33(3):608-612.
Authors:HE Ying  ZHANG Yu-jun  WANG Li-ming  YOU Kun  ZHOU Yi  SUN Xiao-min  LIU Zhen-min
Institution:1. Key Lab of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China2. Key Lab of Ecosystem Network Observation and Modeling, Institute of Geographic Sciences and Natural Resources Research, Chinese Academy of Sciences, Beijing 100101, China
Abstract:Water vapor is an important meteorological parameter in the atmosphere, TDLAS direct absorption technology combined with open-path monitoring was used in order to achieve large-scale regional atmospheric water vapor concentration detection with high sensitivity, high accuracy and fast response, and to correct the remote sensing data. The large-scale regional laser detection system for water vapor was designed and the absorption line of water vapor molecules near 1.27 μm was chosen as the goal line. The system performance was verified in conjunction with a multiple reflection cell, that the system limit sensitivity was 14.803 mmol·mol-1 in optical path of 40 m. The continuous field experiment in 1 420 m optical path at the Yucheng Integrated Experimental Station, CAS was completed with this system which worked stably. Then the measured data was compared with the data of a gas analyzer LI-7500 in eddy correlation observation system at the same site, and the data consistency was good. A new method for water vapor concentration monitoring in the complex field of non-uniform underlying surface was provided.
Keywords:Laser absorption spectroscopy  Open-path  H2O  Large-scale region  
本文献已被 CNKI 等数据库收录!
点击此处可从《光谱学与光谱分析》浏览原始摘要信息
点击此处可从《光谱学与光谱分析》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号