首页 | 本学科首页   官方微博 | 高级检索  
     检索      

等离子体发射光谱测定燃油中钠、钒和铝的研究
引用本文:魏海军,关德林,孙培廷,王宏志,王泽恩,骆泽平,李韶辉.等离子体发射光谱测定燃油中钠、钒和铝的研究[J].光谱学与光谱分析,2006,26(2):340-343.
作者姓名:魏海军  关德林  孙培廷  王宏志  王泽恩  骆泽平  李韶辉
作者单位:1. 大连海事大学轮机工程学院,辽宁,大连,116026
2. 中国石油大连润滑油研发中心,辽宁,大连,116032
摘    要:利用等离子体发射光谱,通过试验优化,确定了影响钠、钒和铝元素的背景等效浓度各因素的最佳工作参数:入射功率、载气流量和辅助气流量,其中钠的入射功率(P)950 W、载气流量(N)0.6 L·min-1、辅助气流量(A)1.0 L·min-1;钒的入射功率1 150 W、载气流量0.5 L·min-1、辅助气流量1.1 L·min-1;铝的入射功率1 150 W、载气流量0.6 L·min-1、辅助气流量1.0 L·min-1.结果表明,该方法具有重现性好、灵敏度高、线性范围宽和精密度高等优点.本方法的精密度在1.7%~2.2%之间,线性范围0~100 mg·L-1,加标回收试验的回收率在96%~105%之间.

关 键 词:燃油  等离子体发射光谱  钠、钒、铝  精密度  加标回收率
文章编号:1000-0593(2006)02-0340-04
收稿时间:2005-01-28
修稿时间:2005-04-28

Study on Determination of Natrium, Vanadium and Aluminum Contents in Fuel Oil by ICP-AES
WEI Hai-jun,GUAN De-lin,SUN Pei-ting,WANG Hong-zhi,WANG Ze-en,LUO Ze-ping,LI Shao-hui.Study on Determination of Natrium, Vanadium and Aluminum Contents in Fuel Oil by ICP-AES[J].Spectroscopy and Spectral Analysis,2006,26(2):340-343.
Authors:WEI Hai-jun  GUAN De-lin  SUN Pei-ting  WANG Hong-zhi  WANG Ze-en  LUO Ze-ping  LI Shao-hui
Institution:Marine Engineering College, Dalian Maritime University, Dalian 116026, China.
Abstract:The present paper considers synthetically all kinds of factors affecting excitation spectrum under traditional measurement conditions of fluorescence matter in liquor using plasma atomic emission spectra. The input power, carrier gas flow and assistant gas flow for BEC of Na, V, Al were optimized by testing. The input power, carrier gas flow and assistant gas flow for Na are 950 W, 0.6 L x min(-1) and 1.0 L x min(-1), respectively. The input power, carrier gas flow and assistant gas flow for V are 1 150 W, 0.5 and 1.1 L x min(-1), respectively. The input power, carrier gas flow and assistant gas flow for Al are 1 150 W, 0.6 and 1.0 L x min(-1), respectively. The result shows that the method is sensitive, accurate, linear in a wide range and highly precise. The precision is between 1.7%-2.2%, the linear ranges are between 0-100 mg x L(-1) and recoveries are between 96%-105%.
Keywords:Fuel oil  Plasma atomic emission spectroscopic analysis  Natrium  vanadium and aluminum  Precision  Recovery
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号