GFAAS法直接测定化妆品中的铅
引用本文:徐天源,苏文周.GFAAS法直接测定化妆品中的铅[J].光谱学与光谱分析,1997,17(3):94-98.
作者姓名:徐天源  苏文周
作者单位:广州市卫生防疫站
摘    要:本文介绍了石墨炉原子吸收光谱法测定化妆品中的铅,大多数样品经适当的溶解就可直接测定,线性范围0.020~1.6ng,检出限0.010ng,相对标准偏差0.8~6.7%,回收率97~104%。

关 键 词:化妆品    石墨炉原子吸收

DETERMINATION OF LEAD IN COSMETIC BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY
T Xu,W Su,Z Zhuo.DETERMINATION OF LEAD IN COSMETIC BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY[J].Spectroscopy and Spectral Analysis,1997,17(3):94-98.
Authors:T Xu  W Su  Z Zhuo
Institution:Guangzhou Health and Anti-Epidemic Station, 510080 Guangzhou.
Abstract:A method is described for the determination of Pb in cosmetic by graphite furnace AAS. The samples were directly determined after most of them were solved. The dynamic range,detection limit, relative standard deviation and recovery are 0.020ng-1.6ng, 0.010ng, 0. 8-6.7%, 97-104% respectrively.
Keywords:GFAAS    Cosmetic    Lead  