首页 | 本学科首页   官方微博 | 高级检索  
     检索      

环境卫星HJ1A超光谱成像仪在轨辐射定标及光谱响应函数敏感性分析
引用本文:高海亮,顾行发,余 涛,李小英,巩 慧,李家国,朱光辉.环境卫星HJ1A超光谱成像仪在轨辐射定标及光谱响应函数敏感性分析[J].光谱学与光谱分析,2010,30(11):3149-3155.
作者姓名:高海亮  顾行发  余 涛  李小英  巩 慧  李家国  朱光辉
作者单位:1. 中国科学院遥感应用研究所遥感科学国家重点实验室, 北京 100101
2. 中国科学院研究生院, 北京 100049
3. 国家航天局航天遥感论证中心, 北京 100101
4. 河南大学,河南 开封 475001
摘    要:环境卫星HJ1A搭载的超光谱成像仪HSI是我国第一个对地观测的星载高光谱传感器,针对超光谱成像仪缺乏各通道光谱响应函数这一问题,对传统的反射率基法予以改进,提出一种不使用光谱响应函数的场地定标方法。利用敦煌场地2009年8月定标实验数据,实现超光谱成像仪在轨辐射定标。通过构建不同形状的光谱响应函数,分析光谱响应函数形状对最终辐射定标结果产生的误差。结果表明,利用新提出的场地定标方法可以实现超光谱成像仪绝对辐射定标,除水汽和氧气吸收通道外,光谱响应函数对定标结果的影响小于3%,采用新定标方法得到的定标系数可以满足应用的需求。

关 键 词:超光谱成像仪  辐射定标  光谱响应函数  敏感性分析  敦煌校正场  
收稿时间:2009-12-22

HJ1A/HSI Radiometric Calibration and Spectrum Response Function Sensitivity Analysis
GAO Hai-liang,GU Xing-fa,YU Tao,LI Xiao-ying,GONG Hui,LI Jia-guo,ZHU Guang-hui.HJ1A/HSI Radiometric Calibration and Spectrum Response Function Sensitivity Analysis[J].Spectroscopy and Spectral Analysis,2010,30(11):3149-3155.
Authors:GAO Hai-liang  GU Xing-fa  YU Tao  LI Xiao-ying  GONG Hui  LI Jia-guo  ZHU Guang-hui
Institution:1. State Key Laboratory of Remote Sensing Science, Jointly Sponsored by the Institute of Remote Sensing Applications of Chinese Academy of Sciences and Beijing Normal University, Beijing 100101, China2. Graduate University of Chinese Academy of Sciences, Beijing 100049, China3. The Center for National Spaceborne Demonstration, Beijing 100101, China4. Henan University, Kaifeng 475001, China
Abstract:Hyper spectrum imager (HSI) loaded on HJ-1A satellite is Chinese first spaceborne hyperspectrum sensor. Since the HSI has no spectrum response function of all channels, the usually used calibration method-reflectance based method has been modified, and a new calibration method is proposed, in which the spectrum response function is neglected. Based on the calibration experiment data of Dunhuang in Aug., 2009, the HSI sensor was calibrated on orbit. The different kinds of spectrum response were constructed based on the formula, and the errors of calibration results with different spectrum response function were analyzed. The results show, expecting for the channels of water vapor and oxygen absorption channel, the influence of spectrum response function in other channel is less than 3%, and the calibration result based on new calibration method can satisfy the application requirement.
Keywords:Hyper-spectrum imager  Radiometric calibration  Spectrum response function  Sensitivity analysis  Dunhuang test site  
本文献已被 CNKI 等数据库收录!
点击此处可从《光谱学与光谱分析》浏览原始摘要信息
点击此处可从《光谱学与光谱分析》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号