首页 | 本学科首页   官方微博 | 高级检索  
     检索      

激光等离子体无源电探针探测及光谱诊断的比较分析
引用本文:刘桐,杨立军,王立君,王浪平.激光等离子体无源电探针探测及光谱诊断的比较分析[J].光谱学与光谱分析,2014,34(2):289-292.
作者姓名:刘桐  杨立军  王立君  王浪平
作者单位:1. 天津大学材料科学与工程学院,天津 300072
2. 天津大学天津市现代连接技术重点实验室,天津 300072
3. 哈尔滨工业大学先进焊接与连接国家重点实验室,黑龙江 哈尔滨 150001
基金项目:国家自然科学基金项目(51175374), 天津市应用基础及前沿技术研究计划项目(11JCYBJC06100)和哈尔滨工业大学先进焊接与连接国家重点实验室项目(AWPT-M12-08)资助
摘    要:提出一种利用无源电探针探测激光焊接光致等离子体的方法。采用光电同步采集系统对激光焊接光致等离子体进行研究,利用无源电探针和光纤式光谱仪探测光致等离子体,利用等离子鞘层理论分析电信号,并运用相对光强法计算出光致等离子体的电子温度,比较同步光电信号分析结果。将不涂覆表面物质以及表面分别涂覆KF和TiO2三种情况下的计算结果进行对比,对影响结果准确性的因素进行分析。研究结果表明通过无源探针法计算等离子体温度与光谱信号计算结果基本吻合,准确度受等离子体离子质量的影响。无源电探针法能够反映激光焊接光致等离子体内温度变化,具有较好的实时性,可以作为激光等离子体监测手段。

关 键 词:无源电探针  光谱诊断  光致等离子体  电子温度    
收稿时间:2013/4/26

A Comparative Analysis of the Passive Electric Probe Detection and Spectrum Diagnosis of Laser-Induced Plasma
LIU Tong,YANG Li-jun,WANG Li-jun,WANG Lang-ping.A Comparative Analysis of the Passive Electric Probe Detection and Spectrum Diagnosis of Laser-Induced Plasma[J].Spectroscopy and Spectral Analysis,2014,34(2):289-292.
Authors:LIU Tong  YANG Li-jun  WANG Li-jun  WANG Lang-ping
Institution:1. School of Materials Science and Engineering, Tianjin University, Tianjin 300072, China2. Tianjin Key Laboratory of Advanced Joining Technology, Tianjin University, Tianjin 300072, China3. State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, Harbin 150001, China
Abstract:An approach to detecting laser-induced plasma using passive probe was brought up. The plasma of laser welding was studied by using a synchronous electric and spectral information acquisition system, the laser-induced plasma was detected by a passive electric probe and fiber spectrometer, the electrical signal was analyzed on the basis of the theory of plasma sheath, and the temperature of laser-induced plasma was calculated by using the method of relative spectral intensity. The analysis results from electrical signal and spectral one were compared. Calculation results of three kinds of surface circumstances, which were respectively coated by KF, TiO2 and without coating, were compared. The factors affecting the detection accuracy were studied. The results indicated that the results calculated by passive probe matched that by spectral signal basically, and the accuracy was affected by ions mass of the plasma. The designed passive electric probe can be used to reflect the continuous fluctuation of electron temperature of the generated plasma, and monitor the laser-induced plasma.
Keywords:Passive probe  Spectrum diagnosis  Laser-induced plasma  Electron temperature
本文献已被 CNKI 等数据库收录!
点击此处可从《光谱学与光谱分析》浏览原始摘要信息
点击此处可从《光谱学与光谱分析》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏