首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Absorption line profile recovery based on TDLS and MEMS micro-mirror for photoacoustic gas sensing
Authors:Li Li  Arsad Norhana  Stewart George  Thursby Graham  Uttamchandani Deepak  Culshaw Brian  Yi-ding Wang
Institution:State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012, China. dawnjlu@gmail.com
Abstract:A novel and efficient absorption line recovery technique is presented. A micro-electromechanical systems (MEMS) mirror driven by an electrothermal actuator is used to generate laser intensity modulation through the mirror reflection. Tunable diode laser spectroscopy (TDLS) and photoacoustic spectroscopy (PAS) are used to recover the target absorption line profile which is compared with the theoretical Voigt profile. The target gas is 0.01% acetylene (C2H2) in a nitrogen host gas. The laser diode wavelength is swept across the P17 absorption line of acetylene at 1535.4 nm by a current ramp, and an erbium-doped fibre amplifier (EDFA) is used to enhance the optical intensity and increase the signal-to-noise ratio (SNR). A SNR of about 35 is obtained with 100 mW laser power from the EDFA. Good agreement is achieved between the experimental results and the theoretical simulation for the P17 absorption line profile.
Keywords:Micro-electro-mechanical-systems( MEMS)  Laser intensity modulation  Absorption line profile recovery  Tunable diode laser spectroscopy  Photo-acoustic gas sensing
本文献已被 万方数据 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏