微波消解/ICP-MS法测定烟草中微量元素含量
引用本文:孙雨安,宋世丘,王国庆,魏丽芳,李振兴.微波消解/ICP-MS法测定烟草中微量元素含量[J].光谱学与光谱分析,2010,30(7):1968-1971.
作者姓名:孙雨安  宋世丘  王国庆  魏丽芳  李振兴
作者单位:1. 郑州轻工业学院应用化学系,河南 郑州 450002
2. 郑州轻工业学院河南省表界面科学重点实验室,河南 郑州 450002
基金项目:国家自然科学基金项目 
摘    要:采用2 mL 50% HNO3和1 mL 47% H2O2作为消解体系,最终消解液酸度在2%左右对烟草样品进行微波消解,标准溶液采用2% HNO3稀释,添加Ge和Rh内标元素,直接进行ICP-MS分析。此方案避免采用浓酸,可省去赶酸或稀释的繁琐步骤,延长仪器相关部件使用寿命,消除由于样品溶液与标准溶液酸度差别较大带来的误差。测试考察了烟草中30种微量元素,给出7个烟草产区样品中8种微量元素的测定结果。方法检出限为0.006~1.133 ng·mL-1,相对标准偏差0.90%~5.66%,Cu和Y回收率93%~102%。结果表明,文章所提出的微波消解方法适用于烟草中多种微量元素的同时测定,烟草样品微量元素含量与烟草产地、类别有紧密联系。

关 键 词:电感耦合等离子体质谱  微波消解  烟草  微量元素  
收稿时间:2009-08-10

Determination of Trace Elements in Tobaccos by Microwave Digestion/ICP-MS Method
SUN Yu-an,SONG Shi-qiu,WANG Guo-qing,WEI Li-fang,LI Zhen-xing.Determination of Trace Elements in Tobaccos by Microwave Digestion/ICP-MS Method[J].Spectroscopy and Spectral Analysis,2010,30(7):1968-1971.
Authors:SUN Yu-an  SONG Shi-qiu  WANG Guo-qing  WEI Li-fang  LI Zhen-xing
Institution:1. Department of Applied Chemistry, Zhengzhou University of Light Industry, Zhengzhou 450002, China2. Henan Provincial Key Laboratory of Surface & Interface Science, Zhengzhou University of Light Industry, Zhengzhou 450002, China
Abstract:2 mL 50% HNO3 and 1 mL 47% H2O2 were chosen for tobaccos digestion, and the acidity of final digestion solution was confined to about 2%. Standard solutions were diluted with 2% HNO3. The digestion solutions were determined by ICP-MS directly after adding internal standard elements Ge and Rh. In stead of using concentrated acid, this method not only can leave out the process of drying or dilution and extended the life of relevant components of the instrument, but also eliminate the errors of the inconsistency between digestion solutions and standard solutions could be eliminated. The contents of 30 trace elements, the results of eight representatives of which were provided, in tobaccos from seven areas were determined. The detection limits of measured elements were from 0.006 to 1.133 ng·mL-1. The relative standard deviations were from 0.90% to 5.66%. The recovery rates of two elements (Cu, Y) were from 93% to 102%. The results showed that this method proposed could be applied to multielement simultaneous determination of tobaccos, and there is a deep relationship between the contents of the trace elements and the production place and classification of tobaccos.
Keywords:ICP-MS  Microwave digestion  Tobacco  Trace element  