首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Heat transfer and friction factor correlation development for double-pass solar air heater having V-shaped ribs as roughness elements
Authors:A Sharma  G Bharadwaj  Varun
Institution:1. Department of Mechanical Engineering, GLA, University, Mathura, UP, India;2. Department of Mechanical Engineering, National Institute of Technology, Hamirpur, HP, India
Abstract:In this present study, an experimental investigation has been carried out for a roughened double-pass solar air heater. The respective variation in other parameters, such as relative roughness pitch (p/e), relative roughness height (e/Dh), and angle of attack (α), were 5–20, 0.022–0.044, and 30°–75°, respectively. The effect of roughness and operating parameters on Nusselt number (Nu) and friction factor (f) has been determined, and the results are compared with those of a smooth absorber plate; considerable enhancement in both heat transfer and friction factor is noticed. Utilizing these experimental data, correlations for Nusselt number and friction factor correlations were also developed.
Keywords:heat transfer  friction factor  Nusselt number  double-pass solar air heater
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号