METHODS OF HEAT LOSS MEASUREMENT FOR A THERMOHYDRAULIC FACILITY |
| |
Authors: | J Sanders |
| |
Institution: | Commission of the European Communities, Joint Research Centre , Safety Technology Institute , Ispra, Italy |
| |
Abstract: | Three methods, using different thermal transients, are proposed to measure the heat loss of a thermohydraulic facility. They can he used for loop-type facilities, with circulation pumps, and for vessel-type facilities, with fluid at saturation. The analysis of uncertainties of the measurement results can help to design a heat loss experiment for a specific application. Examples are presented of heat loss measurements at the LOBI-MOD2 facility, which is an integral system thermohydraulic test facility for safety investigations of pressurized water reactor (PWR) nuclear power plants. |
| |
Keywords: | NH3-H2 O NH3-LiNO3 NH3-H2 O-LiNO3 ternary mixture nucleate pool boiling heat transfer coefficient |
|
|