光学速调管改造后辐射段磁场垫补和测量
引用本文:陈念,徐宏亮,刘金英,贾启卡,张赫,何多慧.光学速调管改造后辐射段磁场垫补和测量[J].强激光与粒子束,2003,15(4):401-404.
作者姓名:陈念  徐宏亮  刘金英  贾启卡  张赫  何多慧
作者单位:中国科学技术大学 国家同步辐射实验室,安徽 合肥 230029
基金项目:国家973专项基金(2001CCB01000)资助课题,国家863计划项目资助课题。
摘    要: 合肥国家同步辐射实验室正在开展储存环相干谐波自由电子激光研究,并对原来的光学速调管进行了改造。磁场的垫补和测量方法由原来的整体测量改为分段进行,垫补的使用使各段积分场及位相误差都尽可能小。详述了合肥储存环的光学速调管辐射段磁场垫补的三种方式,测量了垫补前后不同间隙下积分场分布、位相误差及横向均匀度,各项指标都达到了要求。同样的方法将用于色散段和调制段磁场垫补与测量中,为相干谐波自由电子激光研究提供实验保障。

关 键 词:光学速调管  积分场  位相误差  磁场垫补
文章编号:1001-4322(2003)04-0401-04
收稿时间:2002/6/28
修稿时间:2002年6月28日

Magnetic field shimming and measurement of radiator of reconstructed optical klystron
chen nian,xu hong-liang,liu jin-ying,jia qi-ka,zhang he,he duo-hui.Magnetic field shimming and measurement of radiator of reconstructed optical klystron[J].High Power Laser and Particle Beams,2003,15(4):401-404.
Authors:chen nian  xu hong-liang  liu jin-ying  jia qi-ka  zhang he  he duo-hui
Institution:National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China
Abstract:This paper expatiates on the methods marginal, horizontal and vertical shimming magnet block of OK radiator in Hefi storage ring. By means of shimming,the filed integral and phase error can be reduced as much as possible. All the measurement results of magnetic field of optical klystron before and after shimming are given, including the distribution of field integral and phase error on axis, field integral and RMS phase error for different gaps and transverse distribution of field integral. The results reveal that the radiator can meet the requirement of coherent harmonic generation FEL experimental. The same method will be used in the shimming and measurement of modulator and dispersion section of optical klystron.
Keywords:Optical klystron  Field integral  Phase error  Magnetic field shimming  