摘    要: 基于没有附加磁芯复位电路的磁脉冲压缩网络,设计研制了单级磁脉冲压缩系统;介绍了系统电路的工作情况,通过计算给出了系统关键元件的参数;应用Pspice仿真分析软件对系统电路进行仿真,仿真结果显示,负载为500 W时,饱和变压器和磁开关的磁芯所需饱和时间分别为6 ms和500 ns。实验结果表明:系统接200 W负载时,输出脉冲幅值约18.5 kV,下降时间约40 ns,脉冲宽度约70 ns,最高重复频率可达500 Hz;引入高压快速恢复二极管替代续流电感,不仅有效抑制了负载预脉冲,而且输出脉冲尾部的振荡幅值与持续时间都显著减小。

关 键 词:脉冲功率  磁脉冲压缩  磁开关  快速恢复高压二极管
收稿时间:1900-01-01;

Experimental study on one-stage magnetic pulse compression system
ZHANG Dung-dung,YAN Ping,WANG Jue,ZHOU Yuan,SHAO Ta.Experimental study on one-stage magnetic pulse compression system[J].High Power Laser and Particle Beams,2008,20(8).
Authors:ZHANG Dung-dung  YAN Ping  WANG Jue  ZHOU Yuan  SHAO Ta
Institution:1. Institute of Electrical Engineering, Chinese Academy of Sciences, P.O.Box 2703, Beijing 100190, China;2. Graduate University of Chinese Academy of Sciences, Beijing 100049, China
Abstract:A magnetic pulse compression system which does not contain external remagnetization circuits commonly used in magnetic compressors is presented. Principle of operation for the compressor is described. Simulation of pulse compressor working on a 500 Ω resistive load illustrates that in order to realize the desired pulse, 6 ms and 500 ns magnetization period would be required for cores of saturable pulse transformer and magnetic switch, respectively. The one-stage compression system delivers a -18.5 kV, 70 ns pulse width across a 200 Ω load with a fall time of 40 ns and a repetition rate up to 500 Hz. To improve the matching, the inductor in parallel with load is replaced with a fast-recovering HV diode. The experiment shows that the pulse voltage reverse amplitude and damped oscillation d
Keywords:Magnetic pulse compression  Magnetic switch  Fast-recovering HV diode