“聚龙一号”丝阵实验轴向一维X光辐射功率分布
引用本文:黄展常,杨建伦,徐荣昆,李正宏,蒋树庆,叶繁,胡青元,甯家敏,许泽平.“聚龙一号”丝阵实验轴向一维X光辐射功率分布[J].强激光与粒子束,2016,28(12):122001.
作者姓名:黄展常  杨建伦  徐荣昆  李正宏  蒋树庆  叶繁  胡青元  甯家敏  许泽平
作者单位:1.中国工程物理研究院 核物理与化学研究所, 四川 绵阳 621 900
摘    要:通过一维条纹相机诊断系统对聚龙一号(JL-Ⅰ)四类单层丝阵负载进行了轴向X光辐射测量。由于瑞利-泰勒不稳定性的影响,大部分负载表现出两端发光比中间滞后、阳极端发光比阴极端滞后、阳极端发光总强度弱于阴极端的现象。通过不同类型丝阵对比,对于20 mm直径的丝阵,JL-Ⅰ驱动器的匹配负载线质量在0.9 mg/cm附近。轴向辐射同步性与辐射功率之间存在相关性。

关 键 词:Z箍缩    一维条纹像    丝阵X光辐射    轴向同步性
收稿时间:2016-05-12

Axial 1-D X-ray power distribution of wire-array implosions on JL-Ⅰ
Institution:1.Institute of Nuclear Physics and Chemistry,CAEP,P.O.Box 919-212,Mianyang 621900,China
Abstract:Axial X-ray radiations of four types of wire-arrays were diagnosed via 1-D streak camera system on JL-Ⅰ. Because of the influence of Rayleigh-Taylor instability, wire-arrays mostly had the behavior that X-ray rose up later near both cathode and anode than that of the middle, X-ray near anode rose up later than that of cathode and the intensity of X-ray close to anode seemed weaker than that of cathode. With the comparison of different types of wire-arrays, the optimized mass per unit length of a 20 mm diameter wire-array on JL-Ⅰ was about 0.9 mg/cm. Further, there was a correlation between axial radiation synchronization and radiation power.