首页 | 本学科首页   官方微博 | 高级检索  
     检索      

具有时间分辨能力的强流电子束束剖面测量系统
引用本文:江孝国,邓建军,石金水,张开志,杨国君,王远,李成刚,李勤.具有时间分辨能力的强流电子束束剖面测量系统[J].强激光与粒子束,2005,17(7):1070-1074.
作者姓名:江孝国  邓建军  石金水  张开志  杨国君  王远  李成刚  李勤
作者单位:中国工程物理研究院 流体物理研究所,四川 绵阳 621900
基金项目:国防科技基础研究基金资助课题
摘    要: 高能强流电子束的束参数测量是加速器研制过程中重要的一项测量工作,由于光学渡越辐射具有时间响应快、分辨率高等特点而被用于测量电子束的具有时间分辨能力的束剖面、发散角、能量等多个参数;通过电子束束参数的时间分辨测量则能够了解电子束产生、输运中的问题,非常有利于加速器的研究与调试。一种具有时间分辨能力的、利用光学渡越辐射进行高能强流电子束束斑测量的系统在中国工程物理研究院被建立起来,并在12 MeV LIA的电子束束斑的测量中用于电子束传输研究,该系统拍摄图像的间隔时间最小为10 ns,最小的曝光时间为3 ns,具有一次可以拍摄8幅图像的能力,并获得了12 MeV LIA约100 ns内相应的时间分辨的束斑变化情况,观察到了一些过去未观察到的现象,为加速器的研究提供了又一个新测试方法。

关 键 词:光学渡越辐射  束流诊断  强流加速器  分光锥  ICCD
文章编号:1001-4322(2005)07-1070-05
收稿时间:2004-12-24
修稿时间:2004年12月24

Time-resolved measurement system for electron beam profile of high current LIA
JIANG Xiao-guo,DENG Jian-Jun,SHI Jin-Shui,ZHANG Kai-Zhi,YANG Guo-jun,Wang yuan,LI Cheng-gang,Li Qin.Time-resolved measurement system for electron beam profile of high current LIA[J].High Power Laser and Particle Beams,2005,17(7):1070-1074.
Authors:JIANG Xiao-guo  DENG Jian-Jun  SHI Jin-Shui  ZHANG Kai-Zhi  YANG Guo-jun  Wang yuan  LI Cheng-gang  Li Qin
Institution:Institute of Fluid Physics, CAEP, P.O.Box 919-106, Mianyang 621900, China
Abstract:The beam parameters of high energy and high current LIA are very important for the debugging work. For its ultra-fast response and high resolution, OTR is used to measure both spatial and angular profiles of an electron beam. A time-resolved measurement result of an electron beam produced by LIA can provide much more detailed information.Such a time-resolved measurement system for electron beam profile using OTR has been developed recently in the Institute of Fluid Physics of CAEP and has been put into practice. Typical time-resolved measurement results of an electron beam produced by 12 MeV LIA are shown in the paper. Many phenomena are observed for the first time. This system can capture 8 frame images at a time in the minimum time interval of 10ns while the exposure time is 3 ns.The frame time interval has 8 levels which change from 10 ns to 1 280 ns in power of 2 and the exposure time can change in three levels of 3, 5, 10 ns.The image has a resolution of 1 376×1 035 pixels and the object plane size can reach 80mm.This sytem has provided a new measurement method in study of LIA.
Keywords:Optical Transition Radiation(OTR)  Beam diagnostic  LIA  Optical splitting pyramid  ICCD
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《强激光与粒子束》浏览原始摘要信息
点击此处可从《强激光与粒子束》下载免费的PDF全文