Improving motion estimation by accounting for local image distortion
Institution:1. Department of Signal Processing and Communications, Universidad de Alcalá, Madrid, Spain;2. Tecnalia Research & Innovation, Zamudio, Bizkaia, Spain;1. Fisheries and Oceans Canada, Gulf Fisheries Center, PO Box 5030, Moncton, N.B. E1C 9B6, Canada;2. Fisheries and Oceans Canada, Bedford Institute of Oceanography, PO Box 1006, Dartmouth, N.S. B2Y 4A2, Canada;3. IFREMER, Laboratoire Ressources Halieutiques, 150 Quai Gambetta, BP 699 62321 Boulogne sur Mer, France;1. Rock Mechanics Group, Mining Engineering Department, Faculty of Engineering, Shahid Bahonar University of Kerman, P.O. Box 76175-133, Kerman, Iran;2. Control Engineering Group, Electrical Engineering Department, Faculty of Engineering, Shahid Bahonar University of Kerman, P.O. Box 76175-133, Kerman, Iran;3. Faculty of Science and Technology, Federation University Australia, P.O. Box 663, Ballarat, Victoria 3353, Australia
Abstract:Cardiac elastography is a useful diagnostic technique for detection of heart function abnormalities, based on analysis of echocardiograms. The analysis of the regional heart motion allows assessing the extent of myocardial ischemia and infarction. In this paper, a new two-stage algorithm for cardiac motion estimation is proposed, where the data is taken from a sequence of 2D echocardiograms. The method combines the advantages of block-matching and optical flow techniques. The first stage employs a standard block-matching algorithm (sum of absolute differences) to provide a displacement estimate with accuracy of up to one pixel. At the second stage, this estimate is corrected by estimating the parameters of a local image transform within a test window. The parameters of the image transform are estimated in the least-square sense. In order to account for typical heart motions, like contraction/expansion, translation and rotation, a local affine model is assumed within the test window. The accuracy of the new algorithm is evaluated using a sequence of 500 grayscale B-mode images, which are generated as distorted, but known copies of an original ROI, taken from a real echocardiogram. The accuracy of the motion estimation is expressed in terms of errors: maximum absolute error, root-mean-square error, average error and standard deviation. The errors of the proposed algorithm are compared with these of the known block-matching technique with cross-correlation and interpolation in the sub-pixel space. Statistical analysis of the errors shows that the proposed algorithm provides more accurate estimates of the heart motion than the cross-correlation technique with interpolation in the sub-pixel space.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号