Optimization of a universal matchbox on an ultrasonic vibrating system
Authors:X Li  A Meadows  V BabitskyR Parkin
Institution:Wolfson School of Mechanical and Manufacturing Engineering, Loughborough University, Leicestershire LE11 3TU, UK
Abstract:The main scope of the article is to investigate the effect of ferrite cores gap in a universal matchbox on an ultrasonic vibrating system. A gapped transformer mechanism in a universal matchbox has been thoroughly studied. Characteristics of an ultrasonic vibrating system have been recorded such as mechanical vibrations, inductance, resonant frequencies, current and voltage levels as the gap of ferrite cores gradually increases. In addition, the phase difference between the supplied voltage and the current is also computed and displayed in a Lissajous curve in order to determine the optimal gap between two ferrite cores in the universal matchbox. Explanations supplement the experiment results.
Keywords:Gapped transformer  Resonant frequency  Current  Voltage  Inductance