首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Application of ultrasound in preparing pathological sections to reduce processing time
Authors:Chen Qian  Zou Xinye  Cheng Jianchun  Wu Junru
Institution:

aKey Laboratory of Modern Acoustics, Ministry of Education and Institute of Acoustics, Nanjing University, Nanjing 210093, People’s Republic of China

bDepartment of Physics, University of Vermont, Burlington, VT 05405, USA

Abstract:It has been found experimentally that application of sub-mega and low megahertz ultrasound (US) of spatial and temporal averaged intensity Isata up to 10 W/cm2 during the process of preparing pathological sections of the mouse tissue has shortened the processing time from 12 h (without US) to less than half an hour (with US). The experiment has also showed that the processing time reached the shortest for ultrasound f = 200 kHz among the frequencies of 200 kHz, 400 kHz, 600 kHz, 800 kHz and 1 MHz used in this study. It has been proposed that ultrasound inducing non-inertial cavitation enhanced the permeability of cell membrane to liquid. Thus tissue fixation and dehydration were speeded up by application of US.
Keywords:Ultrasound  Tissue processing  Cell membrane permeability  Pathological sections