Sagnac棱镜角公差与干涉光谱仪光谱分辨率的关系分析
引用本文:陈立武,赵葆常,杨建峰,常凌颖,洪新华.Sagnac棱镜角公差与干涉光谱仪光谱分辨率的关系分析[J].光子学报,2006,35(7):1022-1027.
作者姓名:陈立武  赵葆常  杨建峰  常凌颖  洪新华
作者单位:1. 中国科学院西安光学精密机械研究所,西安,710068;中国科学院研究生院,北京,100039
2. 中国科学院西安光学精密机械研究所,西安,710068
基金项目:国家高技术研究发展计划(863计划)
摘    要:根据干涉成像光谱仪光谱分辨率对角向差的要求,通过对实体Sagnac干涉仪结构和光路进行分析,从三个相互垂直的方向出发,研究了光谱分辨率和棱镜角公差之间存在的关系;并推导了满足光谱仪光谱分辨率要求的实体Sagnac干涉棱镜的角公差公式;用实例说明了关系式的应用方法,如果不考虑棱镜变形引起的色散及棱镜的面型误差和付氏镜的残余像差的影响,而只考虑棱镜的角误差对光谱分辨率的影响,则通常情况下干涉棱镜的角公差要求较严,约20″以内.

关 键 词:成像光谱  干涉仪  光谱分辨率  角公差
收稿时间:2005-07-07
修稿时间:2005年7月7日

The Analysis of the Relationship between Angle Tolerance of Sagnac Prism and the Spectrum Differentiation of the Interferometer Spectrometer
Chen Liwu,Zhao Baochang,Yang Jianfeng,Chang Lingying,Hong Xinhua.The Analysis of the Relationship between Angle Tolerance of Sagnac Prism and the Spectrum Differentiation of the Interferometer Spectrometer[J].Acta Photonica Sinica,2006,35(7):1022-1027.
Authors:Chen Liwu  Zhao Baochang  Yang Jianfeng  Chang Lingying  Hong Xinhua
Institution:(1 Xi'an Institute of Optics and Precision Mechanics,Chinese Academy of Sciences,Xi'an 710068 )
(2 Graduate School of Chinese Academy of Sciences, Beijing 100039)
Abstract:The principle of the Sagnac imaging spectrometer was introduced,and the Sagnac interferometers' working way in the imaging spectrometer was illustrated. In this thesis,the structure of the solid Sagnac interferometer were analyzed,and discussion were made which based on the angle error directions' formulas which the spectral resolution of imaging spectrometer required the angle direction error of FT lens have to be met. From three vertical directions the rays were studied which passed through the two prisms adhered by glue,the pathway variation of the rays in the entitative Sagnac interferometer,and were aralyzed the relation by formulas between the spectral resolution and the angle deviation of the prisms were shown;the angle error formulas of the entitative Sagnac interferometer prisms were deduced which could meet the requirement of the spectral resolution of the interferometer spectroscopy;using examples to show the applying method of the formulas. If the dispersive induced by deforming of the shape of the prism and error of surfaces shape of the prism were neglected,only when the angle error of the prism were accounted,the angle error of the prisms should be strictly required,generally it should be less than 20″.
Keywords:Imaging spectrometer  Interferometer  Spectral resolution  Angle deviation