基于铜离子沉积石墨烯涂层锥形光子晶体光纤的硫化氢传感器
引用本文:冯序,杨晓占,黄国家,邓大申,秦祥,冯文林.基于铜离子沉积石墨烯涂层锥形光子晶体光纤的硫化氢传感器[J].光子学报,2017,46(9).
作者姓名:冯序  杨晓占  黄国家  邓大申  秦祥  冯文林
作者单位:1. 重庆理工大学理学院物理与能源系,重庆,400054;2. 广州特种承压设备检测研究院,广州,510663;3. 重庆理工大学理学院物理与能源系,重庆400054;现代光电检测技术与仪器重庆市重点实验室,重庆400054
基金项目:国家自然科学基金,重庆市高校创新团队项目,重庆市和重庆理工大学研究生创新项目,The National Natural Science Foundation of China,the University Innovation Team Building Program of Chongqing,the Postgraduate Research Innovation Project of Chongqing and CQUT
摘    要:提出一种基于铜沉积石墨烯涂层光子晶体光纤马赫-曾德干涉的硫化氢气敏传感器.将45mm光子晶体光纤两端与单模光纤进行拉锥熔接,使得光子晶体光纤的空气孔熔接时形成塌陷层,更好地激发包层模式,形成基于马赫-曾德结构的干涉仪.采用单层石墨烯粉体,加入异丙醇分散液,反复浸涂至光子晶体光纤包层表面形成石墨烯涂层,并沉积铜纳米颗粒,使传感器对硫化氢气体具有高的响应度.实验结果表明,在硫化氢气体浓度为0~60ppm范围内,随着被测气体浓度不断增大,其输出光谱呈现明显蓝移,传感器灵敏度为0.042 03nm/ppm,且线性度良好.该传感器成本低、灵敏度高、结构简单,适用于低浓度硫化氢气体的在线监测.

关 键 词:光纤锥  光子晶体光纤  马赫曾德干涉仪  石墨烯  气体传感器

Hydrogen Sulfide Gas Sensor Based on Cu ion-deposited Graphene-coated Tapered Photonic Crystal Fiber
FENG Xu,YANG Xiao-zhan,HUANG Guo-jia,DENG Da-shen,QIN Xiang,FENG Wen-lin.Hydrogen Sulfide Gas Sensor Based on Cu ion-deposited Graphene-coated Tapered Photonic Crystal Fiber[J].Acta Photonica Sinica,2017,46(9).
Authors:FENG Xu  YANG Xiao-zhan  HUANG Guo-jia  DENG Da-shen  QIN Xiang  FENG Wen-lin
Abstract:A hydrogen sulfide gas sensor based on Cu-deposited graphene-coated tapered Photonic Crystal Fiber (PCF) Mach-Zehnder Intederometer (MZI) was proposed and fabricated.The PCF-MZI was formed by fusion splicing a PCF with length of 45 mm which was sandwiched between two Single-Mode Fibers (SMF),and the air holes of PCF in the splicing regions were fully collapsed,and then it could motivate the cladding modes better.Using isopropanol as dispersion agent,the monolayer powders of graphene were added in the solution and fully dispersed,and then the PCF was dip-coated and sintered repeatedly.Cu-deposited graphene-coated PCF was used to make the sensor produce high sensitivity.The results show that with the increasing concentration of hydrogen sulfide,the output wavelengths appear blue shift,and a high hydrogen sulfide gas sensitivity of 0.042 03 nm/ppm and good linear relationship are obtained within a measurement range from 0 to 60 ppm for hydrogen sulfide gas.The system has the advantages of low cost,high sensitivity and simple structure,especially suitable for low concentration and on-line monitoring of hydrogen sulfide gas.
Keywords:Fiber tapers  Photonic crystal fiber  Mach-Zehnder interference  Graphene  Gas sensor