首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Non-uniformity effects of the inter-foil distance on GEM detector performance
Authors:Yan Huang  Han YI  Zhi-Gang Xiao  Zhao Zhang  Wen-Jing Cheng  Li-Ming Lü  Wei-Hua Yan  Ren-Sheng Wang  Hong-Jie Li  Yan Zhang  Li-Min Duan  Rong-Jiang Hu  Chen-Gui Lu  He-Run Yang  Peng Ma  Hai-Yan Gao
Institution: Department of Physics, Tsinghua University, Beijing 100084, China;
2. Collaborative Innovation Center of Quantum Matter, Beijing 100084, China;
3. Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China;
4. Department of Physics and Triangle Universities Nuclear Laboratory, Duke University, Durham, NC 27708, U. S. A.;
5. Duke Kunshan University, Kunshan, Jiangsu 215316, China
Abstract:The non-uniformity effect of the inter-foil distance has been studied using a gaseous electron multiplication(GEM) detector with sensitive area of 50mm×50mm. A gradient of the inter-foil distance is introduced by using spacers with different heights at the two ends of the foil gap. While the cluster size and the intrinsic spatial resolution show insignificant dependence on the inter-foil distance, the gain exhibits an approximately linear dependence on the inter-foil distance. From the slope, a quantitative relationship between the change of the inter-foil distance and the change of the gain is derived, which can be used as a method to evaluate the non-uniformity of the foil gap in the application of large-area GEM detectors.
Keywords:gaseous electron multiplication  non-uniformity effects  spatial resolution