首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Calculations of operating schemes for a passive harmonic cavity in HLS-Ⅱ
引用本文:樊浩,吴丛凤,刘广超.Calculations of operating schemes for a passive harmonic cavity in HLS-Ⅱ[J].中国物理 C,2012,36(9):895-899.
作者姓名:樊浩  吴丛凤  刘广超
作者单位:National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China
基金项目:Supported by National Natural Science Foundation of China (10675116);Major State Basic Research Development Programme of China (2011CB808301)
摘    要:A passive higher harmonic cavity (HHC) will be used in the Hefei Light Source II Project (HLS-Ⅱ) to lengthen the bunch and consequently increase the beam lifetime dominated by Touschek scattering. The effects of constant voltage and constant detuning have been calculated and compared over the operating current from 0.4 to 0.2 A on the bunch lengthening for the passive normal conducting harmonic cavity system in HLS-Ⅱ. The results show that the bunch shape has less change and the lifetime improvement factors are not less than 2.7 over the beam currents for the constant voltage case. The constant voltage operating scheme may be applied to our machine.

关 键 词:harmonic  cavity  lifetime  improvement  bunch  length  operating  scheme
收稿时间:2011-12-16

Calculations of operating schemes for a passive harmonic cavity in HLS-Ⅱ
FAN Hao WU Cong-Feng,LIU Guang-Chao.Calculations of operating schemes for a passive harmonic cavity in HLS-Ⅱ[J].High Energy Physics and Nuclear Physics,2012,36(9):895-899.
Authors:FAN Hao WU Cong-Feng  LIU Guang-Chao
Institution:National Synchrotron Radiation Laboratory,University of Science and Technology of China,Hefei 230029,China
Abstract:A passive higher harmonic cavity(HHC) will be used in the Hefei Light Source II Project(HLS) to lengthen the bunch and consequently increase the beam lifetime dominated by Touschek scattering.The effects of constant voltage and constant detuning have been calculated and compared over the operating current from 0.4 to 0.2 A on the bunch lengthening for the passive normal conducting harmonic cavity system in HLS-Ⅱ.The results show that the bunch shape has less change and the lifetime improvement factors are not less than 2.7 over the beam currents for the constant voltage case.The constant voltage operating scheme may be applied to our machine.
Keywords:harmonic cavity  lifetime improvement  bunch length  operating scheme
本文献已被 CNKI 等数据库收录!
点击此处可从《中国物理 C》浏览原始摘要信息
点击此处可从《中国物理 C》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号