首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Neutron dose measurement in carbon ion radiation therapy at HIRFL (IMP)
引用本文:苏有武,李宗强,李武元,王桂玲.Neutron dose measurement in carbon ion radiation therapy at HIRFL (IMP)[J].中国物理 C,2010,34(5):548-550.
作者姓名:苏有武  李宗强  李武元  王桂玲
作者单位:Institute of Modern Physics, Chinese Academy of Science, Lanzhou 730000,;China; Graduate University of Chinese Academy of Sciences, Beijing 100049, China
基金项目:Supported by Foundation of Director of the Institute of Moderm Physics,Chinese Academy of Sciences,China
摘    要:For radiation protection purposes, the neutron dose in carbon ion radiation therapy at the HIRFL (Heavy Ion Research Facility in Lanzhou) was investigated. The neutron dose from primary ^12C ions with a specific energy of 100 MeV/u delivered from SSC was roughly measured with a standard Anderson-Broun rem-meter using a polyethylene target at various distances. The result shows that a maximum neutron dose contribution of 19 mSv in a typically surface tumor treatment was obtained, which is less than 1% of the planed heavy ion dose and is in reasonable agreement with other reports. Also the T-ray dose was measured in this experiment using a thermo luminescent detector.

关 键 词:兰州重离子加速器  中子剂量  剂量测量  放射治疗  碳离子  进出口  重离子研究装置  辐射防护
收稿时间:2009-7-1
修稿时间:2009-9-11

Neutron dose measurement in carbon ion radiation therapy at HIRFL(IMP)
SU You-Wu, LI Zong-Qiang LI Wu-Yuan WANG Gui-Ling Institute of Modern Physics,Chinese Academy of Science,Lanzhou ,China Graduate University of Chinese Academy of Sciences,Beijing ,China.Neutron dose measurement in carbon ion radiation therapy at HIRFL(IMP)[J].High Energy Physics and Nuclear Physics,2010,34(5):548-550.
Authors:SU You-Wu  LI Zong-Qiang LI Wu-Yuan WANG Gui-Ling Institute of Modern Physics  Chinese Academy of Science  Lanzhou  China Graduate University of Chinese Academy of Sciences  Beijing  China
Institution:SU You-Wu1,2 LI Zong-Qiang1 LI Wu-Yuan1 WANG Gui-Ling1 1 Institute of Modern Physics,Chinese Academy of Science,Lanzhou 730000,China 2 Graduate University of Chinese Academy of Sciences,Beijing 100049,China
Abstract:For radiation protection purposes,the neutron dose in carbon ion radiation therapy at the HIRFL(Heavy Ion Research Facility in Lanzhou) was investigated.The neutron dose from primary 12C ions with a specific energy of 100 MeV/u delivered from SSC was roughly measured with a standard Anderson-Broun rem-meter using a polyethylene target at various distances.The result shows that a maximum neutron dose contribution of 19 mSv in a typically surface tumor treatment was obtained,which is less than 1% of the plane...
Keywords:heavy ion therapy  HIRFL  neutron dose  
本文献已被 CNKI 维普 等数据库收录!
点击此处可从《中国物理 C》浏览原始摘要信息
点击此处可从《中国物理 C》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号