Baseline drift effect on the performance of neutron and γ ray discrimination using frequency gradient analysis
引用本文:刘国福,罗晓亮,杨俊,林存宝,胡青青,彭进先.Baseline drift effect on the performance of neutron and γ ray discrimination using frequency gradient analysis[J].中国物理 C,2013,37(6):65-71.
作者姓名:刘国福  罗晓亮  杨俊  林存宝  胡青青  彭进先
作者单位:Department of Instrument Science and Technology, National University of Defense Technology, Changsha 410073, China
基金项目:Supported by National Natural Science Foundation of China(11175254);the support of the Institute of Nuclear Physics and Chemistry, the Chinese Academy of Engineering Physics, Mianyang, China
摘    要:Frequency gradient analysis (FGA) effectively discriminates neutrons and γ rays by examining the frequency-domain features of the photomultiplier tube anode signal. This approach is insensitive to noise but is inevitably affected by the baseline drift similar to other pulse shape discrimination methods. The baseline drift effect is attributed to factors such as power line fluctuation, dark current, noise disturbances, hum, and pulse tail in front-end electronics. This effect needs to be elucidated and quantified before the baseline shift can be estimated and removed from the captured signal. Therefore, the effect of baseline shift on the discrimination performance of neutrons and γ rays with organic scintillation detectors using FGA is investigated in this paper. The relationship between the baseline shift and discrimination parameters of FGA is derived and verified by an experimental system consisting of an americium-beryllium source, a BC501A liquid scintillator detector, and a 5 GSample/s 8-bit oscilloscope. The theoretical and experimental results both show that the estimation of the baseline shift is necessary, and the removal of baseline drift from the pulse shapes can improve the discrimination performance of FGA.

关 键 词:baseline  drift  frequency  gradient  analysis  digital  discrimination  liquid  scintillator
收稿时间:2012-7-13

Baseline drift effect on the performance of neutron and γ ray discrimination using frequency gradient analysis
LIU Guo-Fu LUO Xiao-Liang YANG Jun,LIN Cun-Bao HU Qing-Qing PENG Jin-Xian.Baseline drift effect on the performance of neutron and γ ray discrimination using frequency gradient analysis[J].High Energy Physics and Nuclear Physics,2013,37(6):65-71.
Authors:LIU Guo-Fu LUO Xiao-Liang YANG Jun  LIN Cun-Bao HU Qing-Qing PENG Jin-Xian
Institution:Department of Instrument Science and Technology, National University of Defense Technology, Changsha 410073, China
Abstract:
Keywords: