Aging of LAB-based liquid scintillator in stainless steel containers |
| |
作者姓名: | 陈海涛 俞伯祥 单卿 丁雅韵 杜冰 刘书通 张烜 周莉 贾文宝 方建 叶星辰 胡维 牛顺利 颜嘉庆 赵航 洪道金 |
| |
作者单位: | 1 Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China;;2 State Key Laboratory of Particle Detection and Electronics, Beijing 100049, China;;3 Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China |
| |
摘 要: | Types 316 and 304 stainless steel are two candidates for the storage vessels and piping systems of LAB-based liquid scintillator (LS) in the JUNO experiment. LS aging experiments are carried out at temperatures of 40℃ and 25℃. After 192 days aging at 40℃, the attenuation length of LS was reduced by 6% in a glass container, 12% in a type 304 stainless steel tank, and 10% in a type 316 stainless steel tank. At 25℃ in 304 and 316 stainless steel tanks, the attenuation length was reduced by 6% after 307 days. The light yield and the absorption spectrum were practically the same as that of the unaged sample. The concentration of element Fe in the LAB-based LS did not show a clear change. Type 316 and 304 stainless steel can be used as vessels and transportation pipeline material for LAB-based LS.
|
关 键 词: | JUNO liquid scintillator aging light yield absorption spectrum attenuation length |
收稿时间: | 2014-9-4 |
修稿时间: | 2014-11-11 |
|
| 点击此处可从《中国物理 C》浏览原始摘要信息 |
| 点击此处可从《中国物理 C》下载免费的PDF全文 |
|