Aging of LAB-based liquid scintillator in stainless steel containers
作者姓名:陈海涛  俞伯祥  单卿  丁雅韵  杜冰  刘书通  张烜  周莉  贾文宝  方建  叶星辰  胡维  牛顺利  颜嘉庆  赵航  洪道金
作者单位:1 Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China;;2 State Key Laboratory of Particle Detection and Electronics, Beijing 100049, China;;3 Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
摘    要:Types 316 and 304 stainless steel are two candidates for the storage vessels and piping systems of LAB-based liquid scintillator (LS) in the JUNO experiment. LS aging experiments are carried out at temperatures of 40℃ and 25℃. After 192 days aging at 40℃, the attenuation length of LS was reduced by 6% in a glass container, 12% in a type 304 stainless steel tank, and 10% in a type 316 stainless steel tank. At 25℃ in 304 and 316 stainless steel tanks, the attenuation length was reduced by 6% after 307 days. The light yield and the absorption spectrum were practically the same as that of the unaged sample. The concentration of element Fe in the LAB-based LS did not show a clear change. Type 316 and 304 stainless steel can be used as vessels and transportation pipeline material for LAB-based LS.

关 键 词:JUNO  liquid  scintillator  aging  light  yield  absorption  spectrum  attenuation  length
收稿时间:2014-9-4
修稿时间:2014-11-11
点击此处可从《中国物理 C》浏览原始摘要信息
点击此处可从《中国物理 C》下载免费的PDF全文