氢化物发生ICP-AES法同时测定纯净水中的砷和汞
引用本文:黄志,刘英萍,张宏.氢化物发生ICP-AES法同时测定纯净水中的砷和汞[J].光谱实验室,2001,18(3):382-384.
作者姓名:黄志  刘英萍  张宏
作者单位:成都市卫生防疫站
摘    要:本文建立了氢化物发生ICP-AES法同时测定纯净水中砷和汞的方法,检出限分别为As1.7ug/L-Hg0.1ug/L,方法精密度(RSD)为As 3.46%,Hg2.85%,回收率为As92%-110%,Hg90-113%。

关 键 词:氢化物发生法  纯净水      同时测定  ICP-AES  电感耦合等离子体发射光谱
文章编号:1004-8138(2001)03-0382-03
修稿时间:2000年10月23

Simultaneous Determination of Arsenic and Mercury in Purified Water by HG-ICP-AES
HUANG Zhi,LIU Ying-Ping,ZHANG Hong.Simultaneous Determination of Arsenic and Mercury in Purified Water by HG-ICP-AES[J].Chinese Journal of Spectroscopy Laboratory,2001,18(3):382-384.
Authors:HUANG Zhi  LIU Ying-Ping  ZHANG Hong
Abstract:A HG-ICP-AES method for simultaneous determination of arsenic and mercury in purified water is proposed.The detection limit of arsenic and mercury is 1.7μg/L and 0.1μg/L respectively.The RSD for arsenic is 3.46% and for mercury is 2.85%.The recovery for arsenic is in the range of 92%—110% and for mercury is in the range of 90%—113%.
Keywords:Hydride Generation  Purified Water  Arsenic  Mercury  