首页 | 本学科首页   官方微博 | 高级检索  
     检索      

在线消解-FIA-光度法测定污水中的溶解态总磷
引用本文:杨颖,秦晓光,程祥圣.在线消解-FIA-光度法测定污水中的溶解态总磷[J].光谱实验室,2006,23(6):1159-1162.
作者姓名:杨颖  秦晓光  程祥圣
作者单位:东海环境监测中心,上海市,200137
摘    要:FIA光度法测定污水中高含量磷酸盐的方法与传统测定方法相比具有简单、快速、准确的优点.本法检出限为0.007mg/L,RSD为7.0%.回收率为86.7%-104%.用于实际样品的分析结果令人满意.

关 键 词:在线消解  流动注射分析仪  污水  总磷
文章编号:1004-8138(2006)06-1159-04
收稿时间:2006-07-28
修稿时间:2006-09-06

Measurement of Dissolved Total Phosphorus in Polluted Water by Real Time Digestion with FIA
YANG Ying,QIN Xiao-Guang,CHENG Xiang-Sheng.Measurement of Dissolved Total Phosphorus in Polluted Water by Real Time Digestion with FIA[J].Chinese Journal of Spectroscopy Laboratory,2006,23(6):1159-1162.
Authors:YANG Ying  QIN Xiao-Guang  CHENG Xiang-Sheng
Institution:East China Sea Environmental Monitoring Center,SOA,Shanghai 200137 ,P. R. China
Abstract:A new method for the measurement of dissolved total phosphorus in polluted water with FIA was studied. The method is simple,fast ,and accurate compared with traditional method. The detection limit is 0. 007mg/L with RSD of 7.0K and the recovery of 86.7%-104%. The results are satisfactory.
Keywords:Real Time Digestion  FIA  Polluted Water  Total Phosphorus  