上喷淋上进气喷淋塔换热性能数值研究
引用本文:朱胜奎,朱群志,张涛.上喷淋上进气喷淋塔换热性能数值研究[J].工程热物理学报,2021,42(2):504-511.
作者姓名:朱胜奎  朱群志  张涛
作者单位:上海电力大学能源与机械工程学院,上海200090;上海电力大学能源与机械工程学院,上海200090;上海电力大学能源与机械工程学院,上海200090
基金项目:国家自然科学基金资助项目(No.51576119)。
摘    要:上喷淋上进气喷淋塔是降低燃煤电厂烟气含湿量的最合适方案。引入用户自定义函数来解决和揭示ST-UD内部的复杂过程,特别是利用已发表的实验数据和其他数值模拟结果对FLUENT模型进行了验证。在此基础上,进行了正交仿真试验,对操作参数的重要性进行了评价,分析了液滴直径、喷淋速度、喷淋水流量和喷淋水温度四个因素与塔效率和冷凝率两个评价指标之间的关系。通过极差分析,在有限的仿真数据内获得了不同评价指标的最优运行条件。喷淋液滴直径和流量是影响塔效率的主要因素,喷淋液滴直径、流量和温度是影响冷凝率的主要因素。通过趋势分析,探讨了不同操作因素对塔效率和冷凝速率的影响。本文的结论可为其它喷淋塔的性能优化提供参考。

关 键 词:烟气除湿  喷淋塔  数值模拟  正交实验法

Numerical Study on the Thermal Performance of a Spray Tower With Upward Spraying and Downward Gas Flow
ZHU Sheng-Kui,ZHU Qun-Zhi,ZHANG Tao.Numerical Study on the Thermal Performance of a Spray Tower With Upward Spraying and Downward Gas Flow[J].Journal of Engineering Thermophysics,2021,42(2):504-511.
Authors:ZHU Sheng-Kui  ZHU Qun-Zhi  ZHANG Tao
Institution:(College of Energy and Mechanical Engineering,Shanghai University of Electric Power,Shanghai 200090,China)
Abstract:The spraying tower with upward spraying and downward gas flowing(ST-UD)has emerged as the most appropriate solution to reduce the moisture content of flue gas in coal-fired power plants.The user defined functions are invited to solve and reveal the complicated processes within ST-UD.Particularly,the FLUENT model is validated with the published experimental data and other numerical simulation results.Then orthogonal simulation experiments were carried out to evaluate the importance of operating parameters and analyze the relationship between four factors(the droplet diameter,spraying velocity;spraying water flow rate and spraying temperature)and two evaluation indices(the tower effectiveness and condensation rate).Through range analysis,optimal operating conditions for different evaluation indices were obtained within the limited simulation scope.Further,diameter and flow rate of the spraying droplets are the main factors affecting the tower effectiveness,and diameter,flow rate and temperature of the spraying droplets are the main factors influencing the condensation rate.Through trend analysis,the effects of different operational factors on the tower effectiveness and condensation rate were discussed.The conclusion of this paper provides a reference for the performance optimization of other spraying towers.
Keywords:flue gas dehumidification  spraying tower  numerical simulation  orthogonal experimental method