首页 | 本学科首页   官方微博 | 高级检索  
     检索      

二维位置灵敏探测器输出图像畸变的修正
引用本文:刘涛,赵勇,单旭,陈向军,徐克尊.二维位置灵敏探测器输出图像畸变的修正[J].原子与分子物理学报,2006,23(4):601-605.
作者姓名:刘涛  赵勇  单旭  陈向军  徐克尊
作者单位:中国科学技术大学近代物理系合肥微尺度物质科学国家实验室,合肥,230026
基金项目:国家自然科学基金(10474090,10134010)
摘    要:高分辨(e,2e)谱仪采用二维位置灵敏探测器同时对能量和角度进行多道测量.二维位置灵敏探测器由级联使用的微通道板和电阻阳极板组成,由于电阻阳极板的边缘效应和制造工艺的缺陷,测量得到的位置图像与实际图像总会有一定的形变,存在一定的非线性.本文针对高分辨(e,2e)谱仪二维位置灵敏探测器输出图像的“桶形”畸变及位置非线性,采用一种简易的冷刻法(用脉冲信号来模拟真实电子束团),检验了二维位置灵敏探测器的Gear型电阻阳极板的线性好坏,并用分割成小三角形的方法找出测量得到的畸变图像与原始真实图像的映射关系,再用此关系对其它测量得到的畸变图像进行修正,并对修正的结果进行了评估.通过修正,由“桶形”畸变所造成的图像扭曲得到明显改善.修正后的x方向非线性由修正前的2.1%变为0.59%.这种检验和修正方法对其它领域类似探测器输出图像的修正也有一定的指导意义.

关 键 词:高分辨(e  2e)谱仪  二维位置灵敏探测器  “桶形”畸变
文章编号:1000-0364(2006)04-0601-05
收稿时间:4/7/2005 12:00:00 AM
修稿时间:2005-04-07

The correction of the image from two-dimensional position-sensitive detector
LIU Tao,ZHAO Yong,SHAN Xu,CHEN Xiang-jun,XU Ke-zun.The correction of the image from two-dimensional position-sensitive detector[J].Journal of Atomic and Molecular Physics,2006,23(4):601-605.
Authors:LIU Tao  ZHAO Yong  SHAN Xu  CHEN Xiang-jun  XU Ke-zun
Institution:Hefei National laboratory for Physical Science at Mieroscale,Modem Physics Department University of Science and Technology of China, Hefei 230026, P. R. China
Abstract:Two-dimensional position-sensitive detector was employed in a recently developed high-energy-resolution(e,2e) spectrometer to simultaneously measure the energies and relative azimuthal angles of the outgoing electrons in a wide range.The position-sensitive detector is composed of micro-channel plates and a Gear-type resistive anode encoder.Due to edge effect and the limitation of manufacturing techniques,the image that we measure will always have distortion from the original one.In the present paper,the non-linearity of the resistive anode encoder in the high-energy-resolution(e,2e) spectrometer was inspected in a simple way by using electric pulses instead of input charge cloud.By dividing the image into small triangles,a mapping relation was established between the distorted image and the original one.Then the spatial distortion of another measured image was corrected according to this relation and the correction results were evaluated.After the correction,the barrel distortion was obviously improved and the integral nonlinearity decreased to 0.59% from 2.1% along x-axis.This method of correction can be extended to the other similar detectors.
Keywords:High-energy-resolution(e  2e) spectroscopy  two-dimensional position-sensitive detector(PSD)  barrel distortion
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《原子与分子物理学报》浏览原始摘要信息
点击此处可从《原子与分子物理学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号