首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Laser-fluorescence diagnostics for condensation in laser-ablated copper plasmas
Authors:A D Sappey  T K Gamble
Institution:(1) Chemical and Laser Sciences Division, CLS-3, Los Alamos National Laboratory, 87545 Los Alamos, N.M., USA
Abstract:We are investigating the thermodynamic conditions under which condensation occurs in laser ablated copper plasma plumes. The plasma is created by XeCl excimer laser ablation (308 nm, 300 mJ/pulse) at power densities from 500–1000 MW/cm2 into backing pressures of helium in the range 0–50 torr. We use laser-induced fluorescence (LIF) to probe velocity and relative density of both atomic copper and the copper dimer molecule, Cu2, which is formed during condensation onset. At low pressure (10 mtorr), the atomic Cu velocity peaks at approximately 2×106 cm/s. Copper dimer time-of-flight data suggest that condensation onset occurs after the Cu atoms have slowed very significantly. Excitation scans of the Cu2A-X (0,0) and (1,1) bands yield a rotational and vibrational temperature in the neighborhood of 300 K for all conditions studied. Such low temperatures support the theory that Cu2 is formed under thermally and translationally cold conditions. Direct laser beam absorption is used to determine the number density of atomic copper. Typical densities attained with 5 torr of helium backing gas are 6–8×1013 cm–3. Rayleigh scattering from particulate is easily observable under conditions favorable to particulate production.
Keywords:36  40
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏