Quantitative evaluation of the microjet velocity and cavitation erosion on a copper plate produced by a spherical cavity focused transducer at the high hydrostatic pressure
Institution:1. State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing 400016, PR China;2. National Engineering Research Center of Ultrasound Medicine, Chongqing 401121, PR China
Abstract:Cavitation erosion at the high hydrostatic pressure causes the equipment to operate abnormally for the huge economic losses. Few methods can quantitatively evaluate the cavitation erosion intensity. In order to solve this problem, the cavitation erosion on a copper plate was carried out in a spherical cavity focused transducer system at the hydrostatic pressure of 3, 6, and 10 MPa. Meanwhile, the corresponding cavitation threshold, the initial bubble radius, and the microjet velocity in the ultrasonic field are theoretically analyzed to determine the dimension and velocity of microjet based on the following hypotheses: (1) the influence of the coalescence on the bubble collapse is ignored; (2) the dimension of the microjet is equal to the largest bubble size without the influence of gravity and buoyancy. Using the Westervelt equation for the nonlinear wave propagation and the Johnson-Cook material constitutive model for the high strain rate, a microjet impact model of the multi-bubble cavitation was constructed. In addition, through the analogy with the indentation test, an inversion model was proposed to calculate the microjet velocity and the cavitation erosion intensity. The microjet geometric model was constructed from the dimension and velocity of the microjet. The continuous microjet impact was proposed according to the equivalent impact momentum and solved by the finite element method. The relative errors of the pit depth are 4.02%, 3.34%, and 1.84% at the hydrostatic pressure of 3, 6, and 10 MPa, respectively, and the relative error in the evolution of pit morphology is 7.33% at 10 MPa, which verified the reliability of the proposed models. Experimental and simulation results show that the higher the hydrostatic pressure, the greater the pit depth, pit diameter, the pit-to-microjet diameter ratio, and the cavitation erosion intensity, but the smaller the pit diameter-to-depth ratio. The cavitation erosion intensity becomes significant with the ongoing ultrasonic exposure. In addition, a comparison of the cavitation pit morphology in the microjet pulsed and continuous impact modes shows that the continuous impact mode is effective without the elastic deformation caused by the residual stress. Using the cavitation pit morphology at the different hydrostatic pressures, the microjet velocity can be estimated successfully and accurately in a certain range, whose corresponding errors at the lower and upper limit are 5.98% and 0.11% at 3 MPa, 6.62% and 9.14% at 6 MPa, 6.54% and 5.42% at 10 MPa, respectively. Our proposed models are valid only when the cavitation pit diameter-to-depth ratio is close to 1. Altogether, the cavitation erosion induced by multi-bubble collapses in the focal region of a focused transducer could be evaluated both experimentally and numerically. Using the cavitation pit morphology and the inversion model, the microjet velocity in a certain range could be estimated successfully with satisfactory accuracy.
Keywords:Multi-bubble cavitation  Microjet velocity  High hydrostatic pressure  Inversion model  Cavitation corrosion intensity  Cavitation threshold
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号