首页 | 本学科首页   官方微博 | 高级检索  
     检索      


A simplified field method for measuring the aggregate adverse deviation of partitions
Authors:Lee-Jong Lee
Institution:Department of Building, Heriot-Watt University, Edinburgh Great Britain
Abstract:This paper describes the investigation of a simplified field method of measuring the aggregate adverse deviation of a partition. In this study, the source spectrum in the source room was assumed to be flat over the sixteen one-third octave frequency bands of 100 Hz to 3150 Hz. Measurement of the overall level difference in dB(A) is proposed.Using real transmission loss data, it was found that there was a linear relationship between the aggregate adverse deviation and the level difference in dB(A). The correlation is very good. The investigations show that a simplified method can be developed to rate partitions according to the criterion specified in the British building regulations. The simplified field method can also be applied to situations which use a different grading curve such as the grading curve for flats in Scotland.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏