首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Radiographic method for measuring the continuum hard X-ray output spectrum of a Plasma Focus device
Authors:V Raspa  C Moreno
Institution:Departamento de Física, FCEyN-UBA, PLADEMA-CNEA and INFIP-CONICET, Pab. 1, Ciudad Universitaria, (1428) Buenos Aires, Argentina
Abstract:A radiographic method is proposed and then applied to infer the continuum part of the hard X-ray spectrum of a 4.7 kJ Plasma Focus from differential absorption measurements on metals. Copper, nickel, titanium and silver samples with thicknesses spanning between 0.1 and 10 mm were employed as filters. The X-ray radiation was detected using a standard radiographic screen-film system. The results show the presence of a dominant peak around 75 keV with significant spectral components in the range of 40 to 200 keV. The method is easy to follow, inexpensive, and allows for calibrated, single shot, spectral measurements.
Keywords:52  59  Px  52  58  Lq  87  59  -e  52  38  Ph
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏