变频压缩机对双蒸发器并联重力供液系统的影响
引用本文:李新平,臧润清,张秋玉,李延贺,张晨旭.变频压缩机对双蒸发器并联重力供液系统的影响[J].低温与超导,2019,47(1):77-81.
作者姓名:李新平  臧润清  张秋玉  李延贺  张晨旭
作者单位:天津商业大学,天津市制冷技术重点实验室,天津市制冷技术工程中心,天津300134;天津商业大学,天津市制冷技术重点实验室,天津市制冷技术工程中心,天津300134;天津商业大学,天津市制冷技术重点实验室,天津市制冷技术工程中心,天津300134;天津商业大学,天津市制冷技术重点实验室,天津市制冷技术工程中心,天津300134;天津商业大学,天津市制冷技术重点实验室,天津市制冷技术工程中心,天津300134
基金项目:天津市高等学校科技发展基金计划重点项目
摘    要:为研究在低温工况下压缩机频率对重力再循环制冷系统的影响,保持库温不变,通过调节压缩机频率,测量重力再循环双蒸发器并联制冷系统的相关参数,并与相同压缩机频率下的直接膨胀供液制冷系统进行对比。结果表明:相同工况下压缩机频率为40Hz、45Hz、50Hz、55Hz和60Hz时,重力再循环供液制冷系统相比直接膨胀供液制冷系统的制冷量分别高2.36%、5.92%、7.16%、8.09%和10.1%;压缩机耗功分别高0.45%、2.92%、4.63%和5.76%;性能系数分别高2.36%、5.92%、7.16%和8.09%。故在低温工况下,重力循环制冷系统优于直接膨胀式制冷系统,且增加压缩机频率可优化重力循环制冷系统运行特性。

关 键 词:变频压缩机  供液方式  制冷量  制冷系数

The effect of frequency conversion compressor on gravity feeding system with double evaporation parallel
Li Xinping,Zang Runqing,Zhang Qiuyu,Li Yanhe,Zhang Chenxu.The effect of frequency conversion compressor on gravity feeding system with double evaporation parallel[J].Cryogenics and Superconductivity,2019,47(1):77-81.
Authors:Li Xinping  Zang Runqing  Zhang Qiuyu  Li Yanhe  Zhang Chenxu
Institution:(Tianjin Key Laboratory of Refrigeration Technology,Tianjin Refrigeration Engineering Teehnology Center,Tianjin University of Commerce,Tianjin 300134,China)
Abstract:In order to study the effect of compressor frequency on the gravity refrigeration system under the low temperature condition and keep the cold storage temperature constant,the parameters of the gravity system with double evaporator tube groups were measured by adjusting the compressor frequency and compared with the direct expansion refrigeration system at the same compressor frequency.The results show that at the compressor frequencies of 35 Hz,40 Hz,45 Hz and 50 Hz,the refrigerating capacity of gravity refrigeration system is 2.82%,9.01%,12.12% and 14.31% higher than direct expansion refrigeration system,the compressor consumption is 0.45%,2.92%,4.63% and 5.76% higher than that of the direct expansion refrigeration system and the coefficient of performance of gravity-recirculation refrigeration system is 2.36%,5.92%,7.16% and 8.09%higher than that of the direct expansion refrigeration system.Therefore,the gravity refrigeration system is superior to the direct expansion refrigeration system under the low temperature condition,and the operation characteristics of the gravity refrigeration system can be optimized by increasing the compressor frequency.
Keywords:Variable frequency compressor  Liquid supply way  Refrigerating capacity  Coefficient of performance