首页 | 本学科首页   官方微博 | 高级检索  
     检索      


High-Resolution Infrared-Vacuum Ultraviolet Photoion and Pulsed Field Ionization-Photoelectron Methods for Spectroscopic Studies of Neutrals and Cations
Institution:Department of Chemistry, University of California, Davis, Davis, California 95616, USA;Department of Chemistry, University of California, Davis, Davis, California 95616, USA;Department of Chemistry, University of California, Davis, Davis, California 95616, USA;Department of Chemistry, University of California, Davis, Davis, California 95616, USA;Department of Chemistry, University of California, Davis, Davis, California 95616, USA;Department of Chemistry, University of California, Davis, Davis, California 95616, USA;Department of Chemistry, University of California, Davis, Davis, California 95616, USA;Department of Chemistry, University of California, Davis, Davis, California 95616, USA
Abstract:We show that by scanning the frequency of a single mode infrared (IR) optical parametric oscillator (IR-OPO) laser to excite the molecular species of interest and fixing the frequency of a vacuum ultraviolet (VUV) laser to photoionize the IR excited species, high-resolution IR spectra of polyatomic neutrals can be obtained with high sensitivity. The fact that this IR-VUV-photoion (IR-VUV-PI) method is based on VUV photoionization probe, and thus, allows the identification of the neutral IR absorber, makes it applicable for IR spectroscopy measurements of isotopemers, radicals, and clusters, which usually exist as impure samples. The highly resolved IR-VUV-PI measurements achieved using the single mode IR-OPO laser have made possible the selection of single rovibrational states of CH3X (X=Br and I), C2H4, and C3H4 for VUV-pulsed field ionization-photoelectron (VUV-PFI-PE) measurements, resulting in rovibrationally resolved photoelectron spectra for these polyatomic molecules. These experiments show that the signal-to-noise ratios of the IR-VUV-PI and IR-VUV-PFI-PE spectra obtained by employing the high-resolution IR-OPO laser are significantly higher than those observed in previous IR-VUV-PI and IR-VUV-PFI-PE studies using a low-resolution IR-OPO laser. Further improvement in sensitivity of IR-VUV-PI and IR-VUV-PFI-PE measurements by using the collinear arrangement of IR-VUV lasers and molecular beam is discussed.
Keywords:Vacuum ultraviolet  Infrared  Pulse-field photoelectron  High resolution
点击此处可从《化学物理学报》浏览原始摘要信息
点击此处可从《化学物理学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号