首页 | 本学科首页   官方微博 | 高级检索  
     检索      

KDP晶体台阶生长动力学的激光干涉实验研究
引用本文:卢贵武,李春喜,王子镐,夏海瑞,孙大亮,于锡玲,关继腾.KDP晶体台阶生长动力学的激光干涉实验研究[J].化学物理学报,2003,16(4):289-292.
作者姓名:卢贵武  李春喜  王子镐  夏海瑞  孙大亮  于锡玲  关继腾
作者单位:北京化工大学化学工程学院,北京化工大学化学工程学院,北京化工大学化学工程学院,山东大学晶体材料国家重点实验室,山东大学晶体材料国家重点实验室,山东大学晶体材料国家重点实验室,石油大学(华东)应用物理系 北京100029,石油大学(华东)应用物理系,东营257062,北京100029,北京100029,济南250100,济南250100,济南250100,东营257062
基金项目:国家自然科学基金资助项目 (2 0 0 76 0 0 1)
摘    要:采用迈克尔逊干涉技术 ,通过测量KDP晶体生长的法向速率和台阶斜率来研究其台阶生长的动力学系数、台阶自由能、溶质在边界层内的扩散特征以及激发晶体生长台阶的位错活性 .实验表明 ,KDP中不同活性位错的台阶动力学系数差异较大 ,例如高活性和低活性台阶动力学系数分别为 10 .3× 10 -2 和 5 .2 1× 10 -2 cm/s,位错源在晶体表面的形状、面积的变化 ,以及Burgers矢量的变化是造成晶体生长动力学测量数据重复性差的主要原因

关 键 词:迈克尔逊干涉  KDP晶体  台阶生长  动力学系数
收稿时间:2002/7/10 0:00:00

A Study on the Step Growth Kinetics of KDP Crystal by Michelson Laser Interferometer Experiment
Lu Guiwu,Li Chunxi,Wang Zihao,Xia Hairui,Sun Daliang,Yu Xiling and Guan Jiteng.A Study on the Step Growth Kinetics of KDP Crystal by Michelson Laser Interferometer Experiment[J].Chinese Journal of Chemical Physics,2003,16(4):289-292.
Authors:Lu Guiwu  Li Chunxi  Wang Zihao  Xia Hairui  Sun Daliang  Yu Xiling and Guan Jiteng
Institution:Lu Guiwu a,c,Li Chunxi a**,Wang Zihao a,Xia Hairui b,Sun Daliang b,Yu Xiling b,Guan Jiteng c
Abstract:The dislocation hillock slope and the normal growth rate determined by this dislocation source were simultaneously measured by using the Michelson laser interferometer technology. The crystal growth kinetic parameters, including the step growth kinetic coefficient and step free energy are measured or calculated and the mass diffusion characters on the step plane and the activity of different dislocation sources are discussed. It has been shown that the step kinetic coefficients have significant differences between high and low-activity dislocation sources. For example, the step kinetic coefficients are calculated to be 10.3×10-2 and 5.21×10-2 cm/s for high-activity and low-activity steps, respectively. The most important conclusion is that the surface diffusion does not play a noticeable role in the crystal growth of KDP. It has been believed that the variations of the shape and size of dislocation sources, along with the change of Burgers vectors, are the main reasons for the poor repeatability of kinetic experimental data of KDP crystals.
Keywords:Michelson laser interferometer technology  KDP crystal  Step growth  Kinetic coefficient
本文献已被 CNKI 维普 等数据库收录!
点击此处可从《化学物理学报》浏览原始摘要信息
点击此处可从《化学物理学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号