Plasma parameter diagnosis using hydrogen emission spectra of a quartz-chamber 2.45 GHz ECRIS at Peking University
Authors:WenBin Wu  HaiTao Ren  ShiXiang Peng  Yuan Xu  JiaMei Wen  Tao Zhang  JingFeng Zhang  AiLin Zhang  Jiang Sun  ZhiYu Guo  JiaEr Chen
Institution:1.State Key Laboratory of Nuclear Physics and Technology & Institute of Heavy Ion Physics,Peking University,Beijing,China
Abstract:A quartz-chamber 2.45 GHz electron cyclotron resonance ion source (ECRIS) was designed for diagnostic purposes at Peking University Patent Number: ZL 201110026605.4]. This ion source can produce a maximum 84 mA hydrogen ion beam at 50 kV with a duty factor of 10%. The root-mean-square (RMS) emittance of this beam is less than 0.12π mm mrad. In our initial work, the electron temperature and electron density inside the plasma chamber had been measured with the line intensity ratio of noble gases. Based on these results, the atomic and molecular emission spectra of hydrogen were applied to determine the dissociation degree of hydrogen and the vibrational temperature of hydrogen molecules in the ground state, respectively. Measurements were performed at gas pressures from 4×10?4 to 1×10?3 Pa and at input peak RF power ranging from 1000 to 1800 W. The dissociation degree of hydrogen in the range of 0.5%-10% and the vibrational temperature of hydrogen molecules in the ground state in the range of 3500-8500 K were obtained. The plasma processes inside this ECRIS chamber were discussed based on these results.
Keywords:
本文献已被 CNKI SpringerLink 等数据库收录!