首页 | 本学科首页   官方微博 | 高级检索  
     检索      

包络调制率和载波频率对听觉时间调制检测能力的影响
引用本文:孟庆林,原猛,牟宏宇,陈友元,冯海泓.包络调制率和载波频率对听觉时间调制检测能力的影响[J].物理学报,2012,61(16):164302-164302.
作者姓名:孟庆林  原猛  牟宏宇  陈友元  冯海泓
作者单位:中国科学院声学研究所东海研究站,上海,200032
基金项目:国家自然科学基金青年科学基金(批准号: 11104316)和上海市自然科学基金 (批准号: 11ZR1446000)资助的课题.
摘    要:通过心理物理实验探讨了包络调制率(<300 Hz)和纯音载波频率(<8 kHz)对听觉时间调制检测能力的影响. 测试信号为以纯音为载波的正弦幅度调制信号, 采用二选一强迫选择法和自适应调整步长的心理物理实验方法, 测试得到不同载波频率条件下的时间调制传递函数. 实验结果表明, 包络调制率和载波频率均会对听觉的时间调制检测能力产生影响. 当载波频率低于2 kHz时, 人耳的检测能力与调制率呈单调递增趋势;当载波频率高于3.5 kHz时, 检测能力也会受到调制率的显著影响, 但没有显著的单调变化趋势. 当调制率在10-100 Hz之间时, 检测能力不随载波频率明显变化;当调制率在150-300 Hz之间时, 调制检测能力随着载波频率上升而下降, 在载波频率达到3.5 kHz时, 调制检测能力不随载波频率显著改变.

关 键 词:听觉心理物理  时间调制  听觉滤波器  人工耳蜗
收稿时间:2011-10-14

Effects of envelope modulation rate and carrier frequency on auditory temporal modulation detection
Meng Qing-Lin,Yuan Meng,Mou Hong-Yu,Chen You-Yuan,Feng Hai-Hong.Effects of envelope modulation rate and carrier frequency on auditory temporal modulation detection[J].Acta Physica Sinica,2012,61(16):164302-164302.
Authors:Meng Qing-Lin  Yuan Meng  Mou Hong-Yu  Chen You-Yuan  Feng Hai-Hong
Institution:Shanghai Acoustics Laboratory, Chinese Academy of Sciences, Shanghai 200032, China
Abstract:The effects of envelope modulation rate (below 300 Hz) and pure-tone carrier frequency (below 8 kHz) on auditory temporal modulation detection ability (TMDA) are investigated through psychophysical experiments. The stimuli are sinusoidal amplitude-modulated signals with pure tone carriers. Two-alternative-forced-choice procedure with adaptive step is used. The temporal modulation transfer functions with different carrier frequencies are measured. Twenty-two normal-hearing subjects (22 to 29 years old) are recruited for this study. Experimental results show that both envelope modulation rate and carrier frequency have significant effects on TMDA. When carrier frequency is below 2 kHz, TMDA improves with the increase of modulation rate. When carrier frequency is above about 3.5 kHz, TMDA is influenced by the variation of carrier frequency, but without significant monotonic trend. When modulation rate is between 10 and 100 Hz, carrier frequency does not affect TMDA. When the modulation rate is between 150 and 300 Hz, TMDA decreases with the increase of carrier frequency until the carrier frequency is above 3.5 kHz.
Keywords:auditory psychophysics  temporal modulation  auditory filter  cochlear implant
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《物理学报》浏览原始摘要信息
点击此处可从《物理学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号