首页 | 本学科首页   官方微博 | 高级检索  
     检索      

微重力条件下与容器连通的毛细管中的毛细流动研究
引用本文:周宏伟,王林伟,徐升华,孙祉伟.微重力条件下与容器连通的毛细管中的毛细流动研究[J].物理学报,2015,64(12):124703-124703.
作者姓名:周宏伟  王林伟  徐升华  孙祉伟
作者单位:1. 中国科学院力学研究所, 中国科学院微重力重点实验室, 北京 100190;2. 北京交通大学土木建筑工程学院, 北京 100044
基金项目:国家自然科学基金(批准号:11032011,11172302)资助的课题.
摘    要:利用落塔的短时微重力条件, 实验研究了与容器连通的毛细管中的流体在微重力条件下的毛细流动过程, 并通过理论分析建立了相应的毛细管中弯月液面高度随时间变化的微分方程. 结果表明, 对于不同的接触角和不同的容器/毛细管参数, 由建立的理论公式得到的数值解结果都与实验结果在定量上较为一致. 此外, 实验中发现, 改变乙醇和去离子水混合液的比例可以明显地改变接触角参数, 但对毛细流动的影响很小, 建立的理论公式也对这一现象给出了合理的解释. 该研究对于预测和分析微流道及空间微重力条件下的毛细流动行为具有明显的应用价值.

关 键 词:毛细流动  毛细管  微重力  接触角
收稿时间:2014-10-09

Capillary-driven flow in tubes connected to the containers under microgravity condition
Zhou Hong-Wei,Wang Lin-Wei,Xu Sheng-Hua,Sun Zhi-Wei.Capillary-driven flow in tubes connected to the containers under microgravity condition[J].Acta Physica Sinica,2015,64(12):124703-124703.
Authors:Zhou Hong-Wei  Wang Lin-Wei  Xu Sheng-Hua  Sun Zhi-Wei
Institution:1. Key Laboratory of Microgravity, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China;2. School of Civil Engineering, Beijing Jiaotong University, Beijing 100044, China
Abstract:The capillary-driven liquid flow in tubes connected to containers under a microgravity condition is systematically studied in a drop tower experimentally. The microgravity time lasts up to 3.6 s and the working liquids are mixtures of ethanol and deionized water with different ratios. Theoretically, based on the previous theory for tubes directly immersed in fluid, a modified formula is developed to describe the change tendency of the height of meniscus with microgravity time for such a container/tube system exposed to a microgravity environment. From the theoretical formula, the numerical results of meniscus height at different microgravity time can be obtained, utilizing the geometrical parameters of container/tube systems and the relevant physical quantities of Eth/H2O mixtures with different ratios. By comparing the numerical results with experimental results for different contact angles between working liquid and container in different container/tube systems, we show that the theoretical model is able to quantitatively predict the capillary-driven flow in tubes connected to containers, and the numerical results have good consistence with the experimental results. In addition, the experimental results also show that though the ratio of ethanol to deionized water can change the contact angle remarkably, it has little influence on the capillary flow if the geometrical parameters of the container/tube systems are the same. This is because not only the contact angle, but also the surface tension and viscosity coefficient of the working liquid change with the ratio of ethanol to deionized water. It is found that when the contact angle increases from 42° to 66°, the surface tension increases from 0.0328 N/m to 0.0443 N/m correspondingly, but the viscosity coefficient decreases from 2.11 cSt to1.49 cSt. As a result, the changes of surface tension and viscosity coefficient offset the influence of the change of contact angle, which can be explained by our theoretical model. Compared with the extensively studied system in which tubes are directly immersed into liquid, the container/tube system studied in this paper is more similar to many actual systems such as fluid transfer systems in the microgravity condition and in micro-fluidic devices. Therefore, this study is useful for predicting and analyzing the capillary flows of these actual systems.
Keywords:capillary flow  capillary tube  microgravity  contact angle
点击此处可从《物理学报》浏览原始摘要信息
点击此处可从《物理学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号