一种基于双波长的光声测温技术
引用本文:廖宇,简小华,崔崤峣,张麒.一种基于双波长的光声测温技术[J].物理学报,2017,66(11):117802-117802.
作者姓名:廖宇  简小华  崔崤峣  张麒
作者单位:1. 上海大学通信与信息工程学院, 上海 200444; 2. 中国科学院苏州生物医学工程技术研究所, 苏州 215163
基金项目:江苏省国际科技合作项目(批准号:BZ2016023)、科技部重点研发项目(批准号:2016YFC0103302)、国家博士后面上项目(批准号:2015M581409)、江苏省面上研究项目(批准号:BK20161235)和苏州市前瞻性应用研究(批准号:SYG201607,SZS201510,SYS201456)资助的课题.
摘    要:光声测温是一种利用光声效应来进行温度监控的新方法,具有非侵入式、高灵敏度和探测深度较深等优点.但现有的单波长光声测温方法极易受到系统及测量环境干扰而导致测量精度降低.为了解决这一问题,本文提出了一种双波长光声温度测量方法.在光声测温理论的基础上,分析推导了双波长光声测温的基本原理,并进行了仿体及离体组织样品的双波长光声测温实验.实验结果显示,与传统单波长模式相比,双波长模式下的光声温度测量误差明显减小,测量精度平均提高35%以上.研究结果表明双波长光声测温方法能够有效提高光声温度测量的精度和稳定性,可作为一种更精准的光声温度监控方法应用于医疗手术等领域.

关 键 词:光声测温  双波长  温度监控
收稿时间:2017-01-09

Photoacoustic temperature measurement based on dual-wavelength method
Liao Yu,Jian Xiao-Hua,Cui Yao-Yao,Zhang Qi.Photoacoustic temperature measurement based on dual-wavelength method[J].Acta Physica Sinica,2017,66(11):117802-117802.
Authors:Liao Yu  Jian Xiao-Hua  Cui Yao-Yao  Zhang Qi
Institution:1. School of Communication and Information Engineering, Shanghai University, Shanghai 200444, China; 2. Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
Abstract:Photoacoustic temperature measurement is a novel technique in which photoacoustic effect is used to measure temperature. It has the advantages of non-invasiveness, high sensitivity and deep penetration depth, which is suitable for monitoring the temperature distribution for the safe deposition of heat energy and efficient destruction of tumor cells during thermotherapy or cryotherapy. However, the present reported methods usually use one single wavelength for photoacoustic temperature measuring and are vulnerable to systematic and environmental influence, including the instability of system caused by fluctuation of laser energy, position displacement of transducer, and tissue complexity, which could reduce the measuring accuracy and stability. To solve this problem, a new photoacoustic temperature measuring method by employing two laser wavelengths is proposed in this paper. Firstly a brief theoretical analysis of dual-wavelengths photoacoustic temperature method is performed based on the linear relationship between photoacoustic signal and tissue temperature under two different wavelengths. Then two different samples including phantom of graphite and ex vivo pig blood are experimented respectively. The experimental temperature is set to be in a range of 26 ℃-48 ℃, which is controlled by a precise hot plate. And for improving the detection accuracy, the dual-wavelengths are selected as 760 and 900 nm for graphite phantom, 820 nm and 860 nm for ex vivo pig blood according to their absorption spectrum repetitively. The obtained results reveal that the temperature measuring correlation coefficients by dual-wavelength method can reach to 0.98 in graphite phantom and 0.99 in ex vivo tissue, respectively. And the average measurement deviation decreases to 0.88 ℃ in dual-wavelength method from 1.31 ℃ for the traditional single wavelength method for graphite phantom. While in ex vivo tissue, the measurement deviation decreases to 0.90 ℃ in dual-wavelength method from the average value 1.45 ℃ for the single wavelength method. Furthermore, the standard deviations of error are respectively reduced by an average of 38% in graphite phantom and an average of 30% in ex vivo tissue, respectively. These results indicate that the dual-wavelength method of photoacoustic temperature measurement can improve both the measuring accuracy and stability, and has a potential to be applied to medical therapy and other biomedical fields.
Keywords:photoacoustic temperature measurement  dual-wavelengths  temperature monitoring